Alarm over IP (AoIP) -Input Output module

The development trends of technical protection are increasingly becoming Internet-oriented.

IP_SEC (IP Security)
(ip-ac.eu) system eliminates all alarm transmission flaws.
It performs three basic functions:
  • Alarm signal transfer from the alarm control panel at the secured building to the monitoring center over the Internet,
  • Constant control over the connection between the secured building and the monitoring center and
  • Alternative alarm signal transfer over telephone lines and/or GSM (GPRS) networks.

The IP_SEC system consists of two components:

TheIP_AC interface (IP Alarm Communicator) is a communication deviceenabling alarm signal transfer from the alarmcontrol panel over the IPnetwork (ADSL, cable, wireless...) and at the same time using thepossibility of transfer over standard telephone lines and GMS (GPRS)networks as backups.
The IP_AC interface has an additional functionensuring its wider applicability. It enables additional Input/Outputconnection assuring all kind of signals to be send from the securedbuilding side to the monitoring centre.

A receiver unit called IP_REC (IPReceiver) is installed at the monitoring center enabling alarm signalreception, control over the connection to the secured building andcommunication with the operating software the monitoring center.

Transmitting alarm over Internet and backup networks

Oncethe alarm goes off at the secured building, the IP_AC interface seizesit, reads the CONTACT-ID information (additionally it can be adapted toany other alarm protocol), reformats it into an IP package and sends thepackage overthe IP network to the monitoring center.

The signalsreceived by the Input/Output module (which is connetcted to the IP_ACmodule) can be handled at the same way as alarm signals.

Thereis an alarm receiver called IP_REC installed in the monitoring centerenabling alarm signal reception and control over the connection to thesecured building over the Internet.

Data transfer takes aboutone second and does not exceed 70 bytes, a size which does not slow downthe Internet connection at the secured building or ar the monitortingcenter.
The capacity of a ping coming from the receiver and beingsend back is a little over 30 bytes which also does not slow down theInternet connection.

What happens when Internet connection is off?

If theInternet connection at the secured building is disconnected, an alarmgoes off at the monitoring center. The disconnection is also detected bythe IP_AC interface which tries to transmit the event over the telephoneline or GSM (GPRS) network (secondary transfer can be prioritized -telephone line or GSM network). If the secondary connections aredisconnected as well, an alarm of general disconnection with the securedbuilding is sent to the monitoring software by the IP_REC receiver.

What isthe most important is that the monitoring center keeps CONSTANT CONTROLOVER THE OPERATION OF THE INTERNET LINE at the secured building. Thereceiver and the interface constantly check their connection in presetadjustable intervals (pings).

IP alarm communication IP_SEC (IP-ac. eu) system provides alarm transmission and line supervision over the Internet.

  • Usage:Alarm Transmission
  • Model Number:2.0
  • Brand Name:I/O module
  • Place of Origin:Slovenia
  • Country:Slovenia
  • telephone:386-2-6202000
Usage: Alarm Transmission
Model Number: 2.0
Brand Name: I/O module
Place of Origin: Slovenia
*Your name:
*Your Email:
*To:Globtel
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters Remaining: 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

We do inquire for you , please wait ...

Building Automation BACnet/IP BMS Ethernet IO System

BA190 BACnet Ethernet IO provides 26 IO board options, including digital input/output, analog input/output, thermocouple and resistance temperature detection, etc., which can be combined into more than 10,000 models to meet a variety of application scenarios, and you can select ...

Come From Beilai Technology Co.,Ltd

Photovoltaic Energy IEC104 Remote Ethernet IO Module

BE190 IEC104 Ethernet IO provides 26 IO board options, including digital input/output, analog input/output, thermocouple and resistance temperature detection, etc., which can be combined into more than 10,000 models to meet a variety of application scenarios, and you can select ...

Come From Beilai Technology Co.,Ltd

Dynamic Environment Monitoring Ethernet SNMP I/O Module

BL197 SNMP Ethernet IO provides 26 IO board options, including digital input/output, analog input/output, thermocouple and resistance temperature detection, etc., which can be combined into more than 10,000 models to meet a variety of application scenarios, and you can select ...

Come From Beilai Technology Co.,Ltd

Industrial IoT IgnitionSCADA Cloud Monitoring MQTT IO Module

BL196 MQTT Ethernet IO provides 26 IO board options, including digital input/output, analog input/output, thermocouple and resistance temperature detection, etc., which can be combined into more than 10,000 models to meet a variety of application scenarios, and you can select ...

Come From Beilai Technology Co.,Ltd

Digital Factory OPC UA MES SCADA Ethernet IO Module

BL195 OPC UA Ethernet IO provides 26 IO board options, including digital input/output, analog input/output, thermocouple and resistance temperature detection, etc., which can be combined into more than 10,000 models to meet a variety of application scenarios, and you can select ...

Come From Beilai Technology Co.,Ltd

Industrial Real Time Ethernet/IP Ethernet IO System

BL193 Ethernet/IP Combined IO provides 26 IO board options, including digital input/output, analog input/output, thermocouple and resistance temperature detection, etc., which can be combined into more than 10,000 models to meet a variety of application scenarios, and you can ...

Come From Beilai Technology Co.,Ltd

Industrial EtherCAT Free Combination Digital and Analog Ethernet IO Module

BL192 EtherCAT Combined IO provides 26 IO board options, including digital input/output, analog input/output, thermocouple and resistance temperature detection, etc., which can be combined into more than 10,000 models to meet a variety of application scenarios, and you can ...

Come From Beilai Technology Co.,Ltd

Industrial PROFINET Ethernet IO Module for Siemens PLC S7-1200/1500

BL191 PROFINET Combined IO provides 26 IO board options, including digital input/output, analog input/output, thermocouple and resistance temperature detection, etc., which can be combined into more than 10,000 models to meet a variety of application scenarios, and you can ...

Come From Beilai Technology Co.,Ltd

Process Automation High Speed Ethernet/IP Distributed IO Module

BLIIOT EtherNet/IP I/O system BL213 featuring plug-and-play installation without the need for tools and emphasizing stability as a primary characteristic. It is designed with industrial-grade components and complies with EMC (Electromagnetic Compatibility) and EMI ...

Come From Beilai Technology Co.,Ltd

BLIIoT Industrial EtherCAT IO Coupler with DIN/DO/AIN/DO IO Module

BLIIOT EtherCAT I/O system BL212 featuring plug-and-play installation without the need for tools and emphasizing stability as a primary characteristic. It is designed with industrial-grade components and complies with EMC (Electromagnetic Compatibility) and EMI (Electromagnetic ...

Come From Beilai Technology Co.,Ltd