Ordering Information
2 Year GasAlertClip Extreme Detectors with Event Logging
GA24XT-H H2S detector
GA24XT-M CO detector
GA24XT-S SO2 detector
GA24XT-X O2 detector
MicroDock II Automatic Test and Calibration System
DOCK2-2-1E-00 MicroDock II base station and H2S docking module
DOCK2-2-1F-00 MicroDock II base station and SO2 docking module
DOCK2-2-1G-00 MicroDock II base station and CO docking module
DOCK2-2-1H-00 MicroDock II base station and O2 docking module
Note: Add suffi x by region:
North America: -N Europe: -E United Kingdom: -U Australia: -A
Accessories
GA-USB2 Infrared DataLink
GPR-PRINTER2 Infrared cordless printer
GA-TS02 GasAlertClip automatic test station
GA-HC-1 Hard hat clip (for use with alligator clips
GA-AG-1 and GA-AG-2)
GA-AG-1 Alligator clip (non-conductive)
GA-CL-1 Belt clip (stainless steel)
GA-NS-1 Neck strap with safety release
GA-TC-1 Test cap and hose
GA-CDT-1 Interactive training CD
SPECIFICATIONS
DETECTOR: Zero-maintenance detector
Gas monitored H2S CO SO2 O2
Sensor range 0-100 ppm 0-300 ppm 0-100 ppm 0-30.0 % by vol.
Low alarm level1 10 ppm 35 ppm
30 ppm (UK/EU)
5 ppm 19.5%
High alarm level1 15 ppm 200 ppm 10 ppm 23.5%
Operating temperature2 -40 to +122oF
-40 to +50oC
-22 to +122oF
-30 to +50oC
-22 to +122oF
-30 to +50oC
-4 to +122oF
-20 to +50oC
Calibration Not required Self-calibrating
1Customized alarm settings available at no extra charge 2Internal vibrator operates to -15 oC / +5 oF
GENERAL SPECIFICATIONS: Rugged composite material with integral concussion-proof boot
Humidity: 5% to 95% RH (non-condensing)
EMI/RFI: Complies with EMC Directive 89/336/EEC
Ingress protection: IP 66/67
Battery: Lithium, non-replaceable
Continuously on: Yes
One-button control: Activation, self-test and alarm event data transmission
Full functional self-test: Verifi es integrity of sensor, circuitry, battery and audible/visual alarms
Sensor: Electrochemical cell (temperature compensated)
Operational life: Two years
INDICATORS AND ALARMS:
Visual alarm: Flashing, wide-angled alarm lens with red quad-LEDs, plus fl ashing ALARM icon
Audible alarm: Pulsing, high-output siren at 95 dB (typical) at 1 ft. (0.3 m)
Vibrator alarm: Internal
Failure alarm: Yes (audible/visual/vibration)
Self-test pass: Yes (audible/visual/vibration)
Other: End of life (audible/visual/vibration)
CONTINUOUS LCD DISPLAY: Status display
Life remaining: Continuously displayed in months, then days, then hours
Two alarm levels: LOW alarm / HIGH alarm
Peak alarm exposure: Records and displays peak alarm exposure, and time elapsed (up to 24 hrs.)
Alarm setpoints: High and low (displayed on demand in ppm or %)
Self-test status: Advises to TEST and that self-test was passed u
TESTS:
Full function self-test: On activation and on demand
Battery: Every two hours (auto)
EVENT LOGGING: Records and transmits up to 10 gas alarm events
Event information: Gas type, peak exposure level (ppm or %); alarm duration in minutes and seconds;
time elapsed since the alarm occurred in days, hours and minutes, life remaining,
serial number, self-tests, cumulative alarm time
Transmission method: Via infrared port to infrared printer or to an IR DataLink
PHYSICAL SIZE:
Size: 1.1 x 2.0 x 3.2 inches / 28 x 50 x 81 mm
Weight: 2.7 oz. / 76 g
WARRANTY: 2 years from activation, plus 1-year shelf life (given 3-5 minutes of alarm per day in
Maintenance freeno sensor or battery replacement, no
calibration, no downtime
Full-function self-test of audible/visual alarms, plus integrity
of sensor, battery and circuitry
Continuously ONone-button activation, test and data
transmission
Comes complete with rugged, stainless-steel alligator belt
clip and test cap
Instructions in local languages included
Protect Yourself
Two years of protection with zero maintenance costs
Continuous, alphanumeric, status LCD shows detector life
remaining, alarm setpoints and advises self-test status
Rugged, IP-66/67 highly water-resistant design
Built-in concussion-proof boot
Records and displays the peak alarm encountered and the
time elapsed since the exposure occurred
Automated self-test with BWs MicroDock II system
Automatic event logging records 10 most recent alarm
events that can be downloaded via built-in IR COM port to a
printer, computer or MicroDock II docking station module
Two alarm levels (Low / High)
Provides typical 95 dB tone and bright, quad-LED
indication on alarm
Internal vibrator alarm
Compact (1.1 x 2.0 x 3.2 in. / 28 x 50 x 81 mm) and
lightweight (2.7 oz. / 76 g)
Provides typical 95 dB tone and bright, quad-LED
indication on alarm
Provides typical 95 dB tone and bright, quad-LED indication on alarm |
Portable carbon dioxide (CO2) infrared detector adopts high accuracy sensor, measuring range available with 0-2000ppm, 0-5000ppm, 0-10000ppm, or 0-10%VOL, 0-20%VOL, 0 to 100% VOL, with LCD display, audible, visual & vibrating alarm, compact size, easy to carry and ...
Come From ATO Gas Detector
Model: CJL100/1000 Description: CJL100/1000CH4and H2SGas Detector MA: MFA150187 KA: KFA150019 ExibI: 320150857 Patent No. ZL 2015 2 0975096.3 Introduction: 1. Detect the gas concentrationof CH4, H2S. It will cause alarm whenconcentration is over standard. 2. Alarm is ...
Come From Xuzhou KY Automation Technology Co., Ltd
GDZH-2H Multi-function Gas leak Detector Handheld Refrigerant gas Leakage Detector Sf6 gas leak detector Introduction: GDZH-2H Multi-function SF6 Gas Analyzer integrates SF6 micro- water detector, SF6 purity tester, and SF6 decomposition analyzer as one. One time field ...
Come From GOLD