Smoke Sensor : Addressable

The MI-ISE and MI-PSE plug-in detectors use a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug in and remove detectors without using a ladder.

The MI-ISE intelligent ionisation sensor incorporates a unique single-source chamber designed to respond quickly and dependably to a broad range of fires. The MI-PSE intelligent optical sensors unique sensing chamber is designed with superior signal to noise ratio. The optical chamber is engineered to sense the presence of smoke produced by a wide range of combustion sources.

The Morley-IAS MI-PSE (optical) and MI-ISE (ionisation) are analogue, addressable, low-profile smoke detectors designed for the ZX series intelligent multi protocol fire alarm control panels. Because the MI-PSE and MI-ISE are analogue addressable, the control panel can provide the operator with a pinpoint description of where the fire is located. The control panel is capable of not only knowing the detectors location but exactly how much smoke is in the chamber of the detector. The detector may be set for different sensitivity settings appropriate to the environment of its location.

Features

Addressable Smoke Sensor : Optical Smoke Sensor

  • Usage:Fire
  • Brand Name:Morley Honeywell
  • Place of Origin:United Kingdom
  • Country:Pakistan
  • telephone:92-051-2802384
Usage: Fire
Brand Name: Morley Honeywell
Place of Origin: United Kingdom
*Your name:
*Your Email:
*To:Al-Fateh International
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters Remaining: 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

We do inquire for you , please wait ...

Smoke fan speed sensor CS1

Deyang YOYIK strong technical force, with CNC lathes, machining centers, 1.6M vertical lathe, 2.5M vertical lathe, 3.2M vertical lathe, 4M vertical lathe, CNC boring machine, gantry planing, gantry milling, 80mm Bending Machine and other sophisticated equipment, Strong welding ...

Come From Dongfang Yoyik Engineering Co., Ltd

Addressable fire smoke detector with addressable fire alarm control system

Instruction manaul of S-6001addressable smoke detector 1.Automatic compensation function. It can be automatically compensated to improve the reliability of the smoke detector, such as external environment (temperature, humidity, dust, static, etc.) factors caused by changes ...

Come From Shenzhen Puzhesi Technology Co., Ltd.

2-Wire Network Fire Alarm Smoke Sensor

Input Voltage: DC12-35V Static Current: not more than50uA (DC 12-35V) Alarm Current:40-80mA (DC 12-30V) Operating Humidity: 10%-95% RH (Non coagulating) Operating Temperature: -10 Celsius- +55 Celsius Alarm Reset: Power off reset LED Indication: Detecting: Green LED flash ...

Come From Shenzhen Usafe Intelligent Technology Co., Ltd