Double beams of the fire alarm system

   

Full name of the radio-infrared "beam breaker-type sensors" (Photoelectric Beam Detector), its basic structure, including target hole, the beam intensity of light, spherical lens, LED light and so on. Its detection principle Naishi by using infrared LED infrared light-emitting diodes, and then by focusing processing optical mirror to do to make the light spread to a very remote from the acceptance by the optical device. When the light is interdict will be issued when the alarm. Infrared is a non-visible light, but will spread out will form a cone projecting beam. No intermittently issued a second infrared light beam 1000, so is the pulsating infrared beam. Thus they can not be transferred to the radio is very remote (600 meters).
Trip means the use of the beam across the detector when someone had control protection zone, Trip invisible infrared beam and trigger alarms. Commonly used for outdoor wall alarm, it is always in pairs: a launch, a receiver. Transmitter emits a beam one or more of the human eye can not see infrared light, the formation of the warning line, there is an object through the light was blocked, the receiver changes the signal, amplified after treatment alarm. Infrared sensor on the radio to select the appropriate response time: too short and easily lead to unnecessary interference, such as the birds fly, small animals pass through, etc.; too long to occur omitted. Usually 10 m / sec to determine the shortest time shading. If the person with a width of 20 cm, then the shortest Trip time is 20 ms. Is greater than 20 ms alarm, no alarm is less than 20 milliseconds.

Double-beam on the radio alarm widely used in urban security, residential, factories, companies, schools, families, villas, warehouses, resources, petroleum, chemical, gas transmission and distribution and many other fields.

Double-beam on the radio alarm - Features

fully sealed rain (fog), dust (worms), etc., all-weather design of integrated structure so that it can work in harsh environments
anti-glare up to 50,000 LUX, built-in automatic adjustment strong light filtering system, to avoid the effects of bright light or car lights
upper and lower optical lens while modifying mechanical design, making adjustments faster, more convenient, more accurate
when encountering fog or inclement weather when the detector will automatically increase the sensitivity (AGC circuit)
High-power Infrared receiver on the tube, low power consumption of digital frequency processing technology
Trip-cycle adjustable beam more flexible and adaptable so that it
horizontal / vertical optical angle easy to adjust, easy to calibrate
precision optical lens technology as well as bus control aggregation technology
modular design to facilitate additions and cascading detectors
engage in high level of RFI / EMI capability
Built-in optical sight, easy to debug
's unique digital filter circuit design
professional anti-jamming optical jacket
99% degree of light-sensitive, thus rendering
Anti-lightning circuit design
C relay outputs
bring rain cover design

Double-beam on the radio alarm - Technical Data

Model: ABT-150
alert Distance: Outdoor 150 meters
beam: 2 bundles
Detection method: infrared pulse adjustable, two-beam-type detector at the same time Trip
Current consumption: 40mA/max
supply voltage: DC13.8 ~ 24V AC11V ~ 18V
ambient temperature: -25 ~ +55
light source: L-band dual-beam infrared LED
Alarm Output: IC relay contact output, contact capacity DC30V/0.5A MAX
induction Speed: 50 ~ 700 ms variable

 

security& protection

  • Place of Origin:China (Mainland)
  • Country:China (Mainland)
  • telephone:86-21-51721485-51721486-51721487
Minimum Order Quantity: 1 Set/Sets
Payment Terms: T/T
Place of Origin: China (Mainland)
*Your name:
*Your Email:
*To:Shanghai Rongphui Co., Ltd.
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters Remaining: 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

We do inquire for you , please wait ...

LPCB conventional infrared reflective beam smoke detector laser beam detector for any fire alarm system

Conventional Reflective Beam Detector has built in Laser beam pointing and Digital guide display for real user friendly alignment method. The Laser beam pointing accurately point the exact location where to mount mirror and with additional digital guide display allows to ...

Come From Shenzhen Puzhesi Technology Co., Ltd.

Fire Alarm System

ZAP FIRE is a specialized service for Fire Alarm System and Fire Sprinkler System in India. ZAP FIRE provides all types ofFire Alarm ...

Come From ZAP FIRE

Addressable fire alarm sounder sound siren for addressable fire alarm system

1.It features as eye-catching, long life and low power consumption with ultra-bright white LED light. 2.Electronic encoding. It can be addressed directly by the electronic coder, which makes the project debugging simple and reliable 3.Integrated structural design, reliable ...

Come From Shenzhen Puzhesi Technology Co., Ltd.