Alarm Control Panel

STANDARD FEATURES
  • UL 864 9th edition approved
  • Analog design using Hochiki\'s advanced DCP protocol for fast and robust communication
  • Up to 127 sensors & modules, plus 127 analog sounder bases, for a total of 254 points possible per loop
  • Uses standard wire, no shielded or twisted pair required on SLC loops
  • Supports Class B (style 4) and Class A (style 6 or 7) SLC loops
  • 4 on board Class B (style Y) NAC circuits rated at 2.5 Amp each
  • Programmable sensitivity levels per device & automatic day/night sensitivity modes
  • Automatic daily calibration & drift compensation routine
  • Large 8-line x 40-character LCD display (320 char.)
  • 2 or 4 loop versions (800 addresses/sub-addr. max.)
  • Dual RS-485 bus for panel network
  • 2 built-in RS-232 interfaces for programming via a PC and serial printer interface
  • 5 on board programmable Form C relays rated at 1 amp at 30VDC (Fire1, Fire2, trouble, supervisory, aux.)
  • 500mA of auxiliary power available rated at 24 VDC
  • Loop Explorer Windows? configuration utility
  • *500 network wide software zones
  • Network Capability of up to 64 panels
  • RS485 slave bus for expansion - up to 32 FN-4127-IO boards or up to 15 FN-LCD-S serial annunciators and up to 16 FN-4127-IO boards
  • Auto-learn feature
  • Built in help and alarm information screens
  • Fire Drill test function
  • Walk Test function
  • Alarm Verification feature
  • FireNET is UL listed for Central Station Service when used with the Bosch D9068 contact dialer
  • Powerful & versatile Cause & Effect programming (up to 500 maximum, network wide) including: *Cause & Effect action, *Disable function configuration, *Test mode configuration

FireNET (9th Edition)
Analog Addressable Fire Alarm Control Panel

  • Country:United States
  • telephone:1-714522-2246
FireNET (9th Edition)
Analog Addressable Fire Alarm Control Panel
*Your name:
*Your Email:
*To:Hochiki America Corporation
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters Remaining: 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

We do inquire for you , please wait ...

Fire Alarm Controller for Energy Storage Power Station

Fire Alarm Controller for Energy Storage Power Station The Fire alarm controller is set in each energy storage cabin, with alarm signal acquisition with the cabin detector, start the Fire extinguishing device, linkage alarm, linkage communication with BMS and other functions. ...

Come From Sichuan Xuxin Technology Co., LTD

BLIIoT Network Fault Monitoring Alarm RTU5028E Control AC Contactor

The Network Fault Monitoring RTU RTU5028E is special designed for remote monitoring Ethernet devices communication status and power supply status. It can detect the Ethernet device fault caused by power supply or network communication. If network communication fault, it can ...

Come From BLIIOT

Remote Cellular wireless 4g 8DI 2DO sms app alarm water level monitoring and control system

S150 is a cost-effective Cellular SMS Controller. The SMS controller features 8 digital inputs, 2 relay outputs, it can be connected to various detectors, such as water level detectors, door sensors, infrared detectors, temperature detectors, humidity detectors, water immersion ...

Come From BLIIOT