out put Voltage 24Vcd
Input Voltage:230Vac
TheZC3panel range represents excellent value foreither new orrefurbishedinstallations where conventional, costeffective equipmentis specified.
Up tofive matching 2 to 8, 16 and32zone repeat panels can be connected toeach appropriate sizedmainpanel via the panel auxiliary supply,repeater interface card(orderedseparately) and screened, two wire,serial links. 24volt d.c.supply isby a further two core connection fromthe main panel.
Access to operator levelisvia a control enable key,located on the front of the panel. Asecondseparate key is required toopen the panel enclosure for accessto theengineering level.
Standardfacilitiesincludeclass change, non latching zones (configurable onany zones),one manwalk test for both detector and sounder circuits,aconfigurationprogramme including various delay modes and alertsounderpulsing in nonalarm zones. A lamp and panel buzzer testfacility isalso included onall panels.
Panelsare provided withfourmonitored alarm circuits (two only for the twozone version), withanoutput of 0.5A each for the two and four zonemodels and 1.0A forthelarger sizes. All sounder circuit wiring is fullymonitored foropenand short circuit faults. A common 24Vdc auxiliarysupply isincluded,together with common outputs for both fire and fault.
All unitsarehoused in robust yet attractive metalenclosures, incorporating adoormounted display panel, providing usercontrols and indications.ZC3panels are compatible with all ZCconventional detection devices.Zonewiring is fully monitored for open,short circuit and detectorremoval,with head out continuity.
Complyingwith the requirements of EN54Parts 2 and4, the ZC3 range is approved byseveral certification bodiesincludingthe Loss Prevention CertificationBoard (LPCB) and is idealfor systemsdesigned to meet a variety of localcodes.
TheZC3range of conventional panels features control andindicationfacilitiesfor 2, 4, 8, 16 and 32 zone systems. Up to amaximum of 32automaticdetectors and/or manual call points can beconnected to eachzone.
The ZC3 range of conventional panels features control and indication facilities for 2, 4, 8, 16 and 32 zone systems.
Delivery Time: | 3-14 days |
Package: | 2/4 zone panel 325x95x3409(all in mm)8 zone panel 325x126x370(all in mm)32 zone panel 399x126x370(all in mm) |
Supply Ability: | 200 Piece/Pieces per Week |
Minimum Order Quantity: | 1 Piece/Pieces |
Payment Terms: | T/T |
Port: | Entebbe |
Usage: | Fire |
Model Number: | ZC |
Brand Name: | ZC Conventional Control Panel |
Place of Origin: | Uganda |
Manual Call Point, Designed for Fire Alarm Systems and Security Alarm system. Key Specifications/Special Features Available for flush or surface mounting Plastic film on glass Test key inserted from side Open circuit with series resistor Suitable for the majority of ...
Come From Shenzhen Puzhesi Technology Co., Ltd.
2 zone panel have Master panel and Slave panel. One Master panel can connect 31 Slave panel, and the Master panel could show the fire and fault of all slave panel. The slave panel can only show itself fire and fault.Key Specifications/Special Features Four Style B (Class B) ...
Come From Shenzhen Puzhesi Technology Co., Ltd.
Conventional Fire Alarm Control Panel with four Zones Key Specifications/Special Features Four Style B (Class B) Initiating Device Circuits (IDCs). All zones accept two-wire smoke detectors and any normally-open contact devices. One built-in, Style Y (Class B) Notification ...
Come From Shenzhen Puzhesi Technology Co., Ltd.