Ionization Smoke Detector

System Sensor 200 Series intelligent plug-in smoke detectors with integral communication provide features that surpass conventional detectors. Detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detectors address to be set with decade address switches, providing exact detector locations for selective maintenance when chamber contamination reaches an unacceptable level.

Model 1251B ionization detector incorporates a unique single source, dual chamber design to respond quickly and dependably to a broad range of fires.

Specification
Height : 2.0 inches (51mm)
Diameter
  • 6.1 Inches installed in B210LP base
  • 4.1 inches (104 mm) installed in B501 base
    Shipping Weight
  • Heat 4.8 oz. (136 g)
  • Photo/phot with heat 5.2oz. (147 g) ion 5.4 oz. (153 g)
    Operating Temprature Range
  • Ion Photeo : 32-1200F (0-490C)
  • Photo with Thermal 32-1000F (0-380C)
  • Thermal : -4-1000F (-20-380C)
  • High Temprature : -4-1500F (-20-660C)
    UL Listed Velocity Range
  • Ion : 0 - 1200 fpm (0 - 6.1 m/sec
  • Photo with Thermal : 4000 fpm
    Suitabe For Installation in ducts
    Insect Screen Hole Size
  • Photo : 0.016 inch (0.41mm) nominal
  • Ion : 0.035 Inch (0.8mm) nominal
    Relative Humidity : 10-93% noncondensing
    Thermal Rating
  • Fixed Temprature Setpoint : 1350F (570C)
  • Rate of Rise Detection : 150F/min (8.30C/min.)
  • High
    Temprature Heat : 1900F (880C)
    Voltage Range : 15-32 Volts DC Peak
    Standby Current (Max. Avg.)
  • Ion/Thermal : 150 pA @ 24 VDC (without communication, LED off) 150 pA @ 24 VDC (one communication every 5 sec. with LED enabled
  • Photo/Photo With Thermal : 250 pA @ 24 VDC (without communication LED off), 300 pa @ 24 VDC (one communication every 5 sec. with LED Enables)
    LED Current (Max.) : 6.5 mA @ 24 VDC (on)

6.1 Inches installed in B210LP base
4.1 inches (104 mm) installed in B501 base
Shipping Weight

  • Country:India
  • telephone:91-91-011-32586889
6.1 Inches installed in B210LP base
4.1 inches (104 mm) installed in B501 base
Shipping Weight
*Your name:
*Your Email:
*To:Deepsons Enterprises
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters Remaining: 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

We do inquire for you , please wait ...

wifi Smoke Detector

1.Tuya App Control WIFI Smoke Detector Wireless Type:Wifi2.4GHz 2.Battery included back- up 3. Large test and mute button 4. Low power consumption Operating Voltage:2-3A battery 5.LED indication, Low battery signal 6.Operating light 7.Low 85dB alarm signal 8. Operated by Tuya ...

Come From shenzhen langen technology co.,ltd

LPCB conventional infrared reflective beam smoke detector laser beam detector for any fire alarm system

Conventional Reflective Beam Detector has built in Laser beam pointing and Digital guide display for real user friendly alignment method. The Laser beam pointing accurately point the exact location where to mount mirror and with additional digital guide display allows to ...

Come From Shenzhen Puzhesi Technology Co., Ltd.

Addressable fire smoke detector with addressable fire alarm control system

Instruction manaul of S-6001addressable smoke detector 1.Automatic compensation function. It can be automatically compensated to improve the reliability of the smoke detector, such as external environment (temperature, humidity, dust, static, etc.) factors caused by changes ...