Fire Alarm and Extinguishing Control Panel "S2000-ASPT"

Fire Alarm and Extinguishing Control Panel "S2000-ASPT"
  • (590K)
S2000-ASPT fire-extinguishing panel is designed for autonomous or centralized (within the ORION integrated security system) fire-fighting in residential and industrial premises (in one zone) using powder, aerosol or gas.
  • Status control of three fire alarm loops, door detector circuits and circuits of manual start detectors
  • Operability testing of starting circuits; open- and short-circuit failure detection
  • Start and operation control of automatic fire-extinguishing equipment; consumption control of fire-extinguishing substances
  • Remote start of automatic fire-extinguishing equipment by commands from the S2000 panel or manual starting devices
  • Adjustable time delay before the start of automatic fire-extinguishing equipment
  • Start of automatic fire-extinguishing equipment using a manual device (detector)
  • Automatic start of fire-extinguishing equipment if two fire detectors have operated in one or two loops
  • Activation of sound and light fire notification (siren, lights etc)
  • Steering ventilation gates (latches) and other equipment
  • Automatic start cancellation if a door of a protected room is open
  • Manual (from device keyboard) or remote (from the S2000 panel) start cancellation of automatic fire-extinguishing equipment and of fire alarm
  • Automatic start activation/deactivation of fire-extinguishing equipment by electronic keys Dallas Touch Memory
  • Control of up to 16 S2000-KPB relay modules
  • Alarm and routine message transmission to the S2000 panel
  • Access restriction to the operating control on the front panel by an electric lock
  • Tampering (breaking into the box) detection
  • Back-up accu-battery (built-in)
  • Mains (AC) and back-up power supply control; discharged battery disconnected automatically
  • Comprehensive auto-diagnostics with fault type indication
SPECIFICATIONS
  • Number of alarm loops - 3
  • Loop voltage - 24 V DC
  • Power supply voltage of 4-wire detectors - 12 V or 24 V
  • Back-up battery - 12 V DC; 7 Ampere-hours
  • Mains voltage - 187 V to 242 V AC
  • Voltage and current of the relay outputs Fire, Fault and Smoke removal 28 V, 2 A/80 V 0,1 A
  • Control outputs for external detectors 28 V, 0,5 A
  • Starting circuit 24 V, 0,5 A
  • Capacity of the Touch Key Memory - 15 keys
  • Dimensions - 310x254x85 mm
  • Weight - 8 kg

Status control of three fire alarm loops, door detector circuits and circuits of manual start detectors

  • Country:Russian Federation
  • telephone:7-495-777-4020
Status control of three fire alarm loops, door detector circuits and circuits of manual start detectors
*Your name:
*Your Email:
*To:BOLID
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters Remaining: 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

We do inquire for you , please wait ...

3Z SIGMA XT - Fire Alarm & Extinguishing Control Panel

zone detection , capable of selecting of cross-zoning to increase reliability and eliminate false activation. ...

Come From Alltec Co. Ltd.

Fire alarm and extinguishing control panel BC06

Brand Name:BC06 Place of Origin:Austria Combined fire alarm and extinguishing panel tested by VdS according to EN54-2, -4 and EN12094-1. ...

Come From LABOR STRAUSS