D7024 Fire Alarm Control Panels

CAD Drawing DWG (MUX Configuration (R14))

CAD Drawing DWG (Layout and Wiring (1 - R14))

CAD Drawing DWG (Layout and Wiring (1))

CAD Drawing DWG (MUX Configuration)

CAD Drawing DWG (Layout and Wiring (2))

CAD Drawing DWG (Layout and Wiring (1 - R14))

CAD Drawing DXF (Layout and Wiring (1))

CAD Drawing DXF (Layout and Wiring (2))

CAD Drawing DXF (MUX Configuration)

A/E Specification [pdf]

Commercial Brochure [pdf]

Data Sheet [pdf]

The D7024 Fire Alarm Control Panels (FACPs) can be used in commercial and public building applications such as schools, universities, manufacturing plants, and health care facilities. They are listed by UL for central station, local, auxiliary, and remote station systems. The D7024 FACPs support four on-board initiating zones that can be expanded to eight using the D7034. Each initiating ...

Features

Four initiating zones (expandable to eight); up to 20 twowire smoke detectors per zone

  • Country:United States
  • telephone:1-888-715-3616
Four initiating zones (expandable to eight); up to 20 twowire smoke detectors per zone
*Your name:
*Your Email:
*To:boschsecurity
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters Remaining: 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

We do inquire for you , please wait ...

Fire Alarm Controller for Energy Storage Power Station

Fire Alarm Controller for Energy Storage Power Station The Fire alarm controller is set in each energy storage cabin, with alarm signal acquisition with the cabin detector, start the Fire extinguishing device, linkage alarm, linkage communication with BMS and other functions. ...

Come From Sichuan Xuxin Technology Co., LTD

Addressable fire smoke detector with addressable fire alarm control system

Instruction manaul of S-6001addressable smoke detector 1.Automatic compensation function. It can be automatically compensated to improve the reliability of the smoke detector, such as external environment (temperature, humidity, dust, static, etc.) factors caused by changes ...

Come From Shenzhen Puzhesi Technology Co., Ltd.

Conventional Fire Alarm Control System Manual Call Point

Manual Call Point, Designed for Fire Alarm Systems and Security Alarm system. Key Specifications/Special Features Available for flush or surface mounting Plastic film on glass Test key inserted from side Open circuit with series resistor Suitable for the majority of ...

Come From Shenzhen Puzhesi Technology Co., Ltd.