Multiple Operation Modes
|
Output operation, auto delay reset, instant reset, manual/auto reset.
|
Adjustable Time Output
|
0.1-999.9 sec., can be input from panel.
|
Multiple Time Ranges
|
0.1 sec., 1 sec., 1min., and 1hr. Users can reset time ranges by themselves.
|
Dual Time Operation Ranges
|
With base-10 (1-9999 sec.) or base-60 (1-99M, 59S) time ranges available.
|
EEPROM Memory
|
Uses an IC to memorize counting values and setting values. Memory will 10 years without battery deterioration.
|
Complete Output Terminals
|
Provide two connections: N. O. and N. C.; and output terminals without connection.
|
|
Time setting rage
|
Uses DIP Switch to select time setting ranges: 0.1-999.9S, 1-9999S, 1-9999M, 1-9999H, 0M, 1S-99M, 59S, 0H, 1M-99H, 59S, 0D, 1H-99D, 23H
|
Input
|
Non-connection input:ENCODER, application: proximity switches; L: 0-3V, H: 6-30V
Connection input: Relay connection, micro-adjustment switches.
|
Output
|
Connection output:from each of the connections (a, b) (AC250V, 3A)
Non-Connection output:NPN capacitor output (DC30V, 0.5A)
|
Output Time
|
Operation or 0.1-999.9 sec. (setting by panel)
|
Output Mode
|
Operation N, R, C (setting by DIP SW)
|
Reset
|
External reset, panel button "RESET," an automatic reset by timing operation.
|
Counting Pause
|
When counting is in process, users can't revise settings, and the terminal for receiving input digits will stop.
|
Saving Memory:
|
EEPROM can last 10 years. Setting values, counting values, and delay values can be memorized (max. 12V, 50mA)
|
Power
|
AC 110V/220V
|
Operating Temperature
|
|
Operating Humidity
|
45~85%RH
|
Digital timers
|