S. NO. | ITEM | TYPE | SDU/MDU | SPECIFICATIONS | USE |
1 | AMPLIFIER | LINE | SDU | Gain=16-24dB, Output Level=105dB?V,Input Operating Range=40-80dB?V,Return Loss-Input=10dB & Output=10dB, Noise Figure=5dB, Max. Current=40-65mA, DC Power passing=1A,30V | Inbetween LNBF & STB to boost the signal strength. Noise also increases so least line amplifier to be used. |
2 | AMPLIFIER | IF | MDU | Freq. range=950-2150MHz,Gain=30dB, Gain Control=0-10dB,Slope Control=0 to 6~8dB,Output Level=115dB?V,Input Operating range=55-95dB?V, Return Loss=10dB, Noise Figure=6dB | For MDU ,connected inbetween LNBF & Tapoffs |
3 | SPLITTER | 2 WAY | MDU | Freq. Range=5-2400MHz,Power Pass Option should be present | For MDU to split signals equally for two wings |
4 | SPLITTER | 4 WAY | MDU | Freq. Range=5-2400MHz,Power Pass Option should be present | For MDU to split signals equally for four wings |
6 | TAP OFF | 8 dB | MDU | Freq. Range=5-2400MHz,1 way tap, Power Pass Option should be present | For MDU, connected inbetween Amplifier(IF) & Multi sw. It will attenuate the Signal Strength as per its value. |
7 | TAP OFF | 10 dB | MDU | Freq. Range=5-2400MHz,1 way tap, Power Pass Option should be present | For MDU, connected inbetween Amplifier(IF) & Multi sw. It will attenuate the Signal Strength as per its value. |
8 | TAP OFF | 15 dB | MDU | Freq. Range=5-2400MHz,1 way tap, Power Pass Option should be present | For MDU, connected inbetween Amplifier(IF) & Multi sw. It will attenuate the Signal Strength as per its value. |
9 | TAP OFF | 18 dB | MDU | Freq. Range=5-2400MHz,1 way tap, Power Pass Option should be present | For MDU, connected inbetween Amplifier(IF) & Multi sw. It will attenuate the Signal Strength as per its value. |
10 | TAP OFF | 22 dB | MDU | Freq. Range=5-2400MHz,1 way tap, Power Pass Option should be present | For MDU, connected inbetween Amplifier(IF) & Multi sw. It will attenuate the Signal Strength as per its value. |
11 | TAP OFF | 25 dB | MDU | Freq. Range=5-2400MHz,1 way tap, Power Pass Option should be present | For MDU, connected inbetween Amplifier(IF) & Multi sw. It will attenuate the Signal Strength as per its value. |
12 | TAP OFF | 30 dB | MDU | Freq. Range=5-2400MHz,1 way tap, Power Pass Option should be present | For MDU, connected inbetween Amplifier(IF) & Multi sw. It will attenuate the Signal Strength as per its value. |
13 | MULTI SWITCH | 2*4 | MDU | Freq. range=950-2150MHz,Tap Gain=2dB,Output Level=100dB?V,Operating IF input level=40-90dB?V,Isolation=H/V=35dB, Out-Out=25dB,Return Loss-Inputs=12dB & Outputs=12dB | For MDU, connected inbetween Tapoffs & STB for 4 customers. It will increase the high frequency signals & deliver to STB |
14 | MULTI SWITCH | 2*8 | MDU | Freq. range=950-2150MHz,Tap Gain=2dB,Output Level=100dB?V,Operating IF input level=40-90dB?V,Isolation=H/V=35dB, Out-Out=25dB,Return Loss-Inputs=12dB & Outputs=12dB | For MDU, connected inbetween Tapoffs & STB for 8 customers. It will increase the high frequency signals & deliver to STB |
15 | CONNECTOR | SPLICE | MDU | Male Splice | To connect IF Amp. & Tappoffs / For cascading two Multi sw |
16 | DC BLOCK TERMINATOR | MDU | 75 ohm | To connect the open trunk ports of Amplifier(IF), Tapoffs, Multisw etc.to prevent signal losses |
satelite and cable TV equipment
Delivery Time: | MSN - pradeepagrawalsynergy@hotmail.com ; Skype Accout - pradeep |
Package: | Synergy Telecom P Ltd.13-15 RPS flats, E-block, Vikaspuri N Delhi,110018...India Phone-91 11 28533349, Mobile 91-98101 38894 ,Fax -91 11 2853 1435, pradeep@rfconnectorhouse.com ; MSN - pradeepagrawalsynergy@hotmail.com ; Skype Accout - pradeepag , My trademanager ID -synergytelecom ; http://www.rfconnector.info/ |
Supply Ability: | Skype Accout - pradeep |
Minimum Order Quantity: | MSN - pradeepagrawalsynergy@hotmail.com ; Skype Accout - pradeep |
Port: | Skype Accout - pradeep |