YL-Clarity data system

: Air/H2 flow will be blocked automatically if auto-ignition is set as OFF

- Automatic flame ignition after checking the FID temperature

: Detector ON after checking flow between reference and sample to protect TCD cell

Safety Function
- Automatic flow & temperature control

: Automatically repeatable runs up to 9,999 analyses

- Run time based control

: Scheduling of system ON and OFF

- Time scheduling function

Economical Function

- Maximum temperature: 450

- Programming ramp/plateaus: 15/16

- Fast cooling down speed : 6.5 min(from 450 to 50)


High Performance Column Oven
- Fast heating speed : up to 100/min

- Stores up to 20 different analytical methods

- Column conditioning function

Easy Operation
- Intuitive user interface for a keyboard


- Remote Time Control : Remote Time Delay and Remote Signal Output

- Stable and precise control with powerful dual CPUs

Features

Powerful Control
- Perfect control of all parameters by Autochro-3000 Data System

- Automatic flame ignition for FID

- Gas saver : Carrier gas and Auxiliary gas can be saved

- High sensitivity : At large amount of sample in split injection

- Flow control : Improved detector stability

- Pressure programming: Reduction in decomposition and loss of sample in splitless injection

  This provides interactive and automated GPC  analysis, including recalibration and GPC reporting,  as well as simplifies the retrieval of GPC data

 GPC Extensions

 

  This is to process data that has been acquired from  selected photo diode array detectors. The spectral  data, together with chromatograms, adds a third  dimension to analytical data analysis.

PDA Extension

 

  The program compares up to 12 selected  parameters calculatedaccording to one of three  pre-selected methods (USP, EP, and JP).These  calculated values are either compared to the users  set limit values for each chromatogram separately  or together for the selected series.

SST (System Suitability Test)

Optional Module

  Each chromatogram can be signed electronically. Signature selection is based on the username or  the signature certificate.

Electronic signature

  It records selected events and operations into a special file and selected operations directly into a  chromatogram.

Audit trail

  YL-Clarity sets up access rights and passwords (including their parameters e.g., minimum  length,  validity, etc.). Each user can define the appearance of their own station.

User accounts

21 CFR Part 11 compliance

  Simultaneous data acquisition from up to four  independent chromatographs,each chromatograph  can acquire data from up to 12 detectors.

 Measuring

  YL-Clarity simultaneously displays a virtually  unlimited number of chromatograms and their  mathematical modification; for example,mutual  deductions or derivations of any order.

Overlay

Data Acquisition

The sophisticated YL-Clarity data system is easy to use and offers extensive data management plus full control of the entire YL9100 HPLC products and YL6100 GC. The software is designed for 21 CFR Part 11 Compliance and through full compatibility with MS Windows XP and Vista seamlessly handles data processing and instrument control using an ultra-reliable LAN interface.

The program compares up to 12 selected parameters calculatedaccording to one of three pre-selected methods (USP, EP, and JP)

  • Type:Educational & Reference
  • Country:South Korea
  • telephone:82-82-31-428-8700
Type: Educational & Reference
*Your name:
*Your Email:
*To:YOUNG LIN INSTRUMENT Co., Ltd.
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters Remaining: 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

We do inquire for you , please wait ...