SI. NO.
|
Test Prescribed in IS: 4990-1993
|
Minimum Value for Conformity
|
Observed Value
|
1.
|
General Fitness Test as per IS: 4020 (Part 3), 1998
|
Squareness measured
|
Confirmed
|
2.
|
Local Planeness Test as per IS: 4020 (Part 4),1998
|
Planess measured to an accuracy of 0.1m
|
Confirmed
|
3.
|
Dimansion and Squareness Test as per IS: 4020 (Part 2), 1998
|
height and width measured within an accuracy of 0.1m
|
Confirmed
|
4.
|
Impact indentation Test as per IS: 4020 (Part 5), 1998
|
Indentation Measured to an accuracy of 0.1mm
|
Confirmed
|
5.
|
Edge Loading Test as per IS: 4020 (Part 7), 1998
|
The deflection measured to an accuracy of 0.1mm
|
Confirmed
|
6.
|
Flexure Test as per IS: 4020 (Part 6), 1998
|
The deflection measured to an accuracy of 0.1mm
|
Confirmed
Confirmed
|
7.
|
Slamming Test as per IS : 4020 (Part 10), 1998
|
50 times on the nail at the rate of 4-5 drops/min
|
Confirmed
|
8.
|
Buckling Test as per IS :4020 (Part 9), 1998
|
Deformation measured to an accuracy of 1mm, 5 min, after application of the load and 15 min. after unloading
|
Confirmed
|
9.
|
Shock Resistance Test as per IS : 4020 (Part 8), 1998
|
4 to 5 shocks minimum
|
Confirmed
|
10.
|
Misuse Test as per IS :4020 (Part 11), 1998
|
Should pass after applying 200 N force to the handle at right angles
|
Confirmed
|
11.
|
End Immersion Test as per IS : 4020
(Part 13), 1998
|
No de-lamination
|
No de-lamination found
|
12.
|
Varying Humidity Test as per IS : 4020 (Part 12), 1998
|
Deviation measures to an accuracy on 1.0mm
|
Confirmed
|
13.
|
Knife Test as per IS :4020 (Part 14), 1998
|
Minimum Pass Standard
|
Excellent Standard
|
14.
|
Screw Withdraw as per IS : 4020 (Part 16), 1998
|
Applied load should be 2.0 mm per min for complete withdrawal of the screw
|
Confirmed
|
15.
|
Glue Adhesive Test as per IS : 4020 (Part 15). 1998
|
There shall be no de lamination
|
No de-lamination found
|
Flush Doors: IS:2202(Part-l,1999) "TROJAN" brand flush doors are made from selected hardwood timber species |