SYSTEM DESCRIPTION
  The Polyseal CR system is a liquid applied, chemicallycured
  urethane system. The system utilizes an epoxy primer
  and two coats of aliphatic polyester urethane. Polyseal CR
  is resistant to chemicals, abrasion and weathering. It will
  not soften in moderate temperature nor embrittle in cold.
  The Polyseal CR system is a proven system for use in a
  wide range of applications.
  FEATURES
  Chemical Resistance Abrasion Resistant
  Meets USDA Criteria UV Resistant
  TYPICAL USES
  Horizontal Concrete and Slabs in:
  Power Generating Plants Warehouse Floors
  Petrochemical Plants Manufacturing Plants
  Pulp and Paper Industry Aircraft Hangars
  Milling and Mining Industry
  SURFACE PREPARATION
  Slabs should be structurally sound and fully cured a minimum
  of 28 days. Test slabs for vapor drive in accordance
  with ASTM D-4263.
  Repair concrete and install Poly-Caulk? 80 for control joints
  according to the product data sheet or a Polyurethane joint
  sealant as necessary. Polyseal CR may crack if applied over
  an elastomeric joint sealant.
  Warranties are issued only on slabs that are mechanically
  (i.e. shotblasting) profiled. Acid etching is not recommended.
  Remove all curing and parting compounds and other surface
  hardeners and coatings.
  A test patch (4 ft. x 4 ft.) of Polyseal CR should be applied to
  ensure proper adhesion.
  Prior to recoating an existing coating, prime the surface with
  Polyprime 21 or 2180 and prepare a test patch, as described
  above, to ensure proper adhesion.
  MIXING
  Polycoat-Staingard 1110 has a limited pot life of 1-2 hours at
  normal temperatures (75
| Whether the need is to protect a brand new parking structure |