DESCRIPTION: Alturdyne Basic Model ARDJ-XXX (kW rating)-060-H* 2001 RATINGS
Package Configuration Generator
- Basic package consists of diesel engine
coupled to generator and assembled on
structural steel skid with unit mounted radiator
and pusher fan, control panel and accessories.
Electronic governor is standard along with flex
fuel lines and fuel/water separator and base
isolation pads.
- The Alturdyne designed/manufactured engine
and generator control panel is unit mounted and
contains ammeter, voltmeter, AM/VM select
switch, frequency meter, voltage adjust rheostat,
oil pressure gauge, water temperature gauge,
three-position mode switch, panel lights, cycler
crank with safeties for overspeed, low oil
pressure, high water temperature and
overcrank. Customer connections and remote
alarms are located on isolated terminal strip.
- Generator leads terminate in an oversize box
or at back of circuit breaker located in adjacent
NEMA 1 box.
Engine
- All engines are in-line, multi-cylinder diesels
with direct injection and have replaceable wet
liners. Units are either naturally aspirated (NA),
turbocharged (T), turbocharged with air
aftercooling (TA) or turbocharged with water
aftercooling (TW). Rotary (R) or in-line (I)
injection pumps are used. Emissions and
acoustics are low. Accessories include fuel
pump, primary and secondary fuel filters, lube oil
pump and cooler, lube oil filter, water pump,
exhaust manifold, jacket water heater, stainless
flex exhaust coupling, insulation blankets, DC
starter and battery charging alternator.
- Generators are four pole, brushless broad
range machines with a single permanently
lubricated, double shielded radial ball bearing
and flywheel disc drive coupling. The revolving
field design contains a direct drive exciter and
stator windings are 2/3 pitch with vacuum epoxy
impregnation. Design is to NEMA and
International Standards and insulation is either
Class F or H. Generators feature a TIF of <50,
low radio interference, a wave form deviation of
<5%, harmonic content of 3% max and a
voltage regulation of 1% with standard static
regulator.
Optional Equipment
- Special voltages up to 600 volts and DC.
The following codes are used:
G - 120/240 single phase
P - 120/208 three phase
R - 277/480 three phase
S - 346/600 three phase
E - 220/380 three phase
X - Special (4,160)
D - DC (Direct Current)
- PMG is available along with 3 phase sensing
which includes a parallel module and
overvoltage protection with engine relief load
acceptance. Additional RF protection is
available.
- Special array of temperature rise (80
DESCRIPTION: Alturdyne Basic Model ARDJ-XXX (kW rating)-060-H* 2001 RATINGS Package Configuration Generator |
Prime Power / Standby Power : 1000 / 1100 KW Engine Model : KTA50-G3 Fuel consumption : 254 L/H Cylinder : 12V Displacement : 50.3 L Genset Dimension : 4618x1850x2750 mm ...