PVC sheathed rubber insulated copper conductor vessel cable

Assembly:
1. Conductor copper, round-shaped, area range of 1.0 to 4.0 mm2, according to class 3, area range of 6 to 400 mm2, according to class 2. 
2. Isolator its allowed to apply synthetic films around the conductors (under the insulation) of cables
3. Insulation insulating rubber. 
4. Twisting Insulated conductors of cables are twisted to form a cable using concentric layers in different directions. It is allowed to twist insulated conductors in concentric layers in one direction. Insulated conductors of two conductor cables of up to and including 4 mm2 of area can be positioned in parallel. Each layer of cables with conductor areas of up to and including 2.5 mm2 has a count conductor and leader conductor. When cabling insulated conductors it is allowed to use a rubber cord as a filler.
5. Isolator a single synthetic film is applied over the insulation of single conductor cables or an outer layer of insulated conductors of cable. 
6. Inner sheath of PVC. It is allowed to apply a synthetic film longitudinally. 
7. Isolator It is allowed to apply a single synthetic film over the inner sheath.
8. Outer sheath of PVC. It is applied over the inner sheath and synthetic film wrapping. For these cables its allowed to only one PVC sheath except for two and three conductor cables 2.5 mm2 of area and greater.

Application:
KNRk vessel cables are intended for use in power and lighting networks, control circuits, alarm units and interconnections.They are designed for fixed laying applications indoors and on the open deck provided that they are protected against solar radiation effects including those of vapors and condensate of oils and fuels, vapors of acids, alkalis, apatite, coal, cement and other dusts, flour from fish and other fish products in fish processing shop and refrigerator room conditions as well under the effects of radial hydrostatic pressure of up to 1.96 MPa (20 kgs/cm2).

Technical details:
Cables are designed for operation in ambient temperature range of..+45 oC to 40 oC
Cables shall be laid and installed without preheating at temperatures not lower than-15 oC
Cables are resistant to the effects of 100 % relative humidity of the air at.. +35 oC
Cables are resistant to vibration and single impact loads
Cables are resistant to sea water
Cables are flameretardant if laid singly
Bending radius during the installation of cables in places where the access is impeded shall account for at least3 outer diameters of cable when the number of bending at one place is not more than two
Bending radius during the installation of fixed cables shall account for at least. 5 outer diameters of cable
Cables shall withstand alternate current voltage test of..2500 V
Electric resistance of insulation at +20 oC at least.120 MOm/km
Continuously permissible temperature of conductor at least+75 oC
Cable construction length at least125 m
Guarantee service life5 years from the day of putting a cable into operation
Minimum service life .25 years


OKP codes:
35 8642 01 KNRk cables

KNRk vessel cables are intended for use in power and lighting networks, control circuits, alarm units and interconnections.They

  • Brand Name:Electrocable works
  • Place of Origin:Russian Federation
  • Country:Russian Federation
  • telephone:7-812-9655629
Package: on wooden drums in 20/40' containers
Minimum Order Quantity: 2000 Meter
Payment Terms: T/T
Brand Name: Electrocable works
Place of Origin: Russian Federation
*Your name:
*Your Email:
*To:Seafartrans Co Ltd
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters Remaining: 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

We do inquire for you , please wait ...

PVC Cable, Copper core PVC insulated and sheathed Electric cable

PVC Cable, Copper core PVC insulated and sheathed Electric cable Conductor: Copper wires, as per IEC 60228 Class 5 Insulation: PVC, maximum working temperature: 70 degree Celsius Armour: Aluminum wire or steel wire or steel tape Sheath: PVC Standards: IEC 60502, IEC 60228, ...

Come From Zhejiang Qinshan Cable Co., Ltd.

Copper core xlpe insulated PVC sheathed electric cable

Copper core xlpe insulated PVC sheathed electric cable Model No.: YJV - 0.6/1.0KV Application: Power Transmission And Lighting Systems Standards: IEC 60502, IEC 60228, GB/T 12706.1-2008 For laying indoors and outdoors, it\'s able to bear certain traction during installation, ...

Come From Zhejiang Qinshan Cable Co., Ltd.

PVCInsulated, Steel Wire / Strip Armoured And PVC Sheathed Control Cable With Copper /Aluminium Conductor

Jacket:PVC Conductor Material:Aluminum Application:Industrial Type:Low Voltage Insulation Material:PVC Brand Name:OrientCab Place of Origin:Delhi India PVC Insulated,Steel/Strip wire armoured Power Cable in Aluminium/Copper Conductor IS:1554 (Part-1) ...

Come From