Low smoke & halogen-free fiame-retardant cable could endure firing test in bundle as GB/T18380(IEC 60332-3). Smoke density in firing should comply with stipulastions of GB/17651 (IEC61034). PH value of solution water of gas seperated out should be less than 4.3, and electric conductivity rate should be no more than 10 ms/mm and comply with stipulations of IEC 60754-2. Fire-resistance cable could endure fire rating test in GB/T19216(IEC60331).
Low smoke Iow halogen fiame-retardant cable could endure firing test in bundle stipulated in GB/T18380(IEC 60332-3), and smoke density in firing should comply with stipulations of GB/T17651 (IEC61034). HCL content of gas separated out in firing should be no more than 100mg/g, and comply with IEC60754-1; 5. Flame-retardant character: 4. Working Frequency Voltage Test: 2. Environment temperature should be no lower than 0 .The min bending radius should be no smaller than 15 times of cable outer diameter. 1. The Max. long-term operating temperature of conductor is no more than 70.Using Feature & Main Technical Performance
It is manufactured as GB/T12706.1 standards. The flame-retardant power cable is manufactured according to Q/ZHGK. It complies with GB/T18380 (IEC60332-3) standards. The fire-resistant power cable is manufactured according to Q/ZHGK. It complies with GB/T19216 (IEC60331) standards.
Executive Standard
It is used to transmit and distribute power on the power line of A.C rated voltage 0.6/1kV. The flame-retardant power cable is suitable for environment with demand on flame-retardant performance. Fire-resistance power cable is used in the environment with high demand on fire-resisting performance such as high-rise building, the big market.
Application
0.6/1kV PVC Insulation Power Cable.
It is used to transmit and distribute power on the power line of A.C rated voltage 0.6/1kV.
Minimum Order Quantity: | 100 Meter |
Payment Terms: | T/T |
Jacket: | PVC |
Conductor Material: | Copper |
Application: | Construction |
Type: | Low Voltage |
Insulation Material: | PVC |
Brand Name: | CCHT |
Place of Origin: | Anhui China (Mainland) |
XLPE electrical wire 4 core power cables are normally used in power transmission and distribution systems. The power cable 4 core XLPE cable is referred to as IEC60502 CU/XLPE/PVC 0.6/1KV. The circular conductor is applied for the size below 16mm² and the shaped conductor is ...
The structure of 10mm 4 core and earth cable+1 earth is designed for application where the earth wires are required according to customer requirements. These 4 core and earth cable are often referred 16mm xlpe 4 core +1 cables XLPE insulated with voltage 0.6/1000v or IEC60502 4 ...
XLPE insulated 3 core power cable is normally used in power transmission and distribution systems. The three core cable wires are referred to IEC60502 CU/XLPE/PVC 0.6/1KV. The circular conductor is applied for the size below 16mm² and the shaped conductor is applied for the ...