970
1133.8
1156.7
16500
1.327
95
61/w
1033.5
Grapefruit
825
890.0
910.0
12900
1.187
95
61/w
795.0
Persimmon
720
724.7
742.6
10510
1.080
95
61/w
636.0
Breadfruit
670
619.4
633.0
8950
.982
75
37/w
556.5
Paw Paw
610
537.5
550.0
7820
.921
75
37/w
477.0
Huckleberry
545
457.4
469.2
6400
.852
75
19/w
397.5
Molles
495
378.8
387.6
5535
.766
60
19/w
336.4
Anona
430
305.8
313.5
4470
.692
60
19/w
266.8
Mulberry
370
247.9
254.8
3620
.632
60
19/w
4/0
Pomegranate
370
251.4
258.7
3450
.626
60
7/w
4/0
Olive
320
204.0
210.5
2740
.570
60
7/w
3/0
Fig
280
166.2
171.9
2260
.522
60
7/w
2/0
Orange
240
135.6
140.7
1790
.477
60
7/w
1/0
Quince
180
84.0
87.1
1220
.373
45
7/w
2
Peach
140
50.8
51.5
790
.285
30
7/w
4
Apricot
135
47.3
48.5
675
.264
30
Solid
4
Pear
105
32.0
33.0
445
.222
30
Solid
6
Apple
AAC
Poly
XLPE
XLPE
Ampacity(Amps)
Weight
Rated Strength(lbs)
Outside Diameter(inches)
Insulation Thickness(mls)
Strand
Size AWG or MCM
Code Name
To determine current ampacity by conductor size,please consult The National Electric Code,latest edition.
For 6201 aluminum conductors diameter equivalent to ACSR construction or 1350 aluminum equivalent.Ampacity ratings based on 75oC conductor temperature 25 oC ambient temperature elevation-sea level.Emissivity 0.91,coefficient of absorption 0.95.Thermal reisitivity of covering-375 oC-Cm2/Watt-CM.Wind speed 2ft/sec in sun.
Available in 500 ft coils or long lengths on reels.The data is approximate and subject to normal manufacturing tolerances.
NOTE:The Code Words as Given Apply to Conventional Polyethylene Line Wire
4.The Diagram of Structure
ICEA S-61-402 and S-66-524
ASTM B-230,B-231,B-232 and B-399
3.Standards
Conductors are aluminum alloy 1350-H19,6210-T81,or ACSR conductors,concentrically stranded and covered for weather proofing with polyethylene,high density polyethylene(HD)or crosslinked polyethylene(XLP).
2.Construction
Covered Line Wire is used primarily for overhead secondary distribution lines.It is not an electrically insulated conductor and is treated as bare conductor when installed.
1.Applications
Covered Line Cable - Aluminum Conductor is used primarily for overhead secondary distribution lines.
Payment Terms: | L/C,D/A,D/P,T/T |
Jacket: | PVC |
Conductor Material: | Aluminum |
Application: | Industrial |
Type: | Other |
Insulation Material: | PVC |
Place of Origin: | Henan China (Mainland) |