19,88
22,20
17,6
10*4,0
22
15,82
-
13,90
13,3
16,82
18,54
13,9
7*4,0
19
13,69
-
11,80
11,3
14,67
-
11,8
4*4,0
33
26,58
28,90
24,66
24,5
26,58
30,75
24,5
37*2,5
30
24,04
26,36
21,72
21,6
24,04
27,85
21,6
27*2,5
26
20,22
22,54
17,90
17,8
20,22
23,65
17,8
19*2,5
24
18,46
20,78
16,14
16,1
19,35
21,95
16,1
14*2,5
23
16,84
19,56
14,92
14,8
17,74
20,65
14,8
10*2,5
19
13,86
-
11,94
11,9
14,78
11,9
7*2,5
19
12,97
-
11,05
11,0
13,89
11,0
5*2,5
18
12,10
-
10,18
10,1
13,03
10,1
4*2,5
30
23,38
26,10
21,46
37*1,5
28
21,19
23,51
19,27
27*1,5
24
17,82
20,54
15,90
19*1,5
23
16,30
19,02
14,38
14*1,5
22
15,24
13,30
10*1,5
18
12,66
10,74
7*1,5
18
11,92
10,00
5*1,5
17
11,4
9,20
4*1,5
28
19,70
37*1,0
26
17,30
27*1,0
23
14,70
19*1,0
22
13,30
14*1,0
20
12,30
10*1,0
18
10,00
7*1,0
17
9,30
5*1,0
16
8,00
4*1,0
- LS, ,
,
- LS, ,
,
,
,
,
Diameter of conductor with copper core, mm
Diameter of conductor with aluminium core, mm
Number and nominal cross- sectional area, mrn 2 Sheath for cables for fire hazard and explosive zones: flexible PVC I of low combustibility, low fire risk flexible PVC. Insulation: flexible PVC, self-extinguishing polyethylene, low fire risk flexible PVC. Cables are produced with screen from aluminium or copper foil or without it, with armour of two steel tapes or without it, with sheath of flexible PVC. Current-conducting core: aluminium or copper wire. Low smoke flame retardant cables ore produced for nuclear power stations and industrial applications. All types of cables have PVC protective covering. These cobles are flame retardant, used for laying in air. Wire armored cables are for use in location where the cable is subject to ultimate tensile stresses. Tape armored cobles are intended for use in locations with possible influences of stray currents and where the cable is not subject to ultimate tensile stresses. The cables without outer covering ore intended for use in buildings, channels, tunnels under aggressive weather conditions. For fixed connection to electric devices, apparatuses, mounting of terminals of electric distributing systems for alternating voltage up to 600 V, with frequency up to 100 Hz or direct voltage up to 1000 V. Plastic Insulated Control Cables |
For fixed connection to electric devices, apparatuses, mounting of terminals of electric distributing systems for alternating |
Copper tape cable is mainly used in anti-interference circuit system. These copper control cables feature a plain annealed cu conductor and PVC insulation and sheath mounting cu tape with a voltage of 450/750v. Copper wire control cable could be designed to have performance of ...
The control cables are also called multi-core control cables or flexible control cables. They are mainly used to signal transmission rather than electric power transmission. The application of control cable wire is mainly in the site of the mechanical and motor industry as the ...
Aerial copper cable are the cables of single-layer or multi-layer aluminum or copper strands twisted on top to extrude the insulation wire. Overhead line is relative to the cable said, that is, and by the tower will be the wire at a certain height to transmit electricity lines. ...