0.6/1kV upto 36Kv
-Conductor:
Solid or stranded copper
-Insulation:
Cross-linked polyethylene/ polyvinyl chloride ( XLPE or PVC)
-Circuit Identication:
The insulation shall be red, black or other colors.
-Filler:
Polypropylene with lapped binding tape
-Inner Sheath:
Polyvinyl chloride (Black)
-Armor:
Galvanized steel wire or double steel tape armor
-Core-covering:
Binding tape
-Outer Sheath:
Polyvinyl chloride/ (Black)
Copper (aluminum) conductor, XLPE/PVC insulated ,PVC sheathed power cables
Copper (aluminum) conductor, XLPE/PVC insulated, PE sheathed power cables
Copper (aluminum) conductor, XLPE/PVC insulated, steel tape armoring(DSTA) PVC sheathed power cables
Copper (aluminum) conductor, XLPE/PVC insulated, steel tape armoring(DSTA), PE sheathed power cables
Copper (aluminum) conductor, XLPE/PVC insulated, steel wire armoring(SWA), PVC sheathed power Cables
Copper (aluminum) conductor, XLPE/PVC insulated, steel wire armoring(SWA), PE sheathed power cables
This series includes:
Al/CU Conductor XLPE/PVC Insulated Thin/Thick steel armored PE Sheathed Power Cable. AL/CU,XLPE/PVC,SWA/DSTA,PVC/PE
Relative manufacturing standards: IEC60505, BS, DIN,ASTM,JIS or other standards.
Application:
It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines,
metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable.
Using features:
1. Rated voltage: Uo/U: 26/35kV, 21/35kV, 12/20 kV (24 kV), 8.7/10kV, 8.7/15kV, 6/6kV, 6/10kV and 0.6/1kV.
2. No. Of core: Single-core, Two-core,Three-core,Four-core,Five-core,Six-core.
3. The highest allowed operating temperature of conductor for long-term working is 90oC. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no
more than 250 degree.
4. D. C. Resistance of the conductor complies with the stipulations of international standar.
5. The environment temperature should be no lower than zero degree when lay. Otherwise it should be preheated.
6. The cable is laid without horizontal drop limit. The Min. Bending radius of cables should be no smaller than 12 times of cable outer diameter.
7. Working Frequency Voltage Test:
For cable with Uo of 3.6kV or lower: 2.5Uo+2kV/5min without puncture.
For cable with Uo of 3.6Kv~18kV: 3.5Uo/5min without puncture.
For cable with Uo of 21kV and 26 kV: 2.5Uo/30min without puncture.
8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable
0.6/1KV PVC insulated power cable
Delivery Time: | 3 weeks |
Package: | export standard packages |
Supply Ability: | 10 Kilometer per Week |
Minimum Order Quantity: | 10 Kilometer |
Payment Terms: | L/C,D/A,D/P,T/T |
Port: | Qingdao |
Jacket: | PVC |
Conductor Material: | Copper |
Application: | Underground |
Type: | Low Voltage |
Insulation Material: | PVC |
Place of Origin: | China (Mainland) |
Hebei Qijie Wire Mesh MFG Co., Ltd. offer Cable-Rod Woven Mesh, an innovative and aesthetically pleasing solution for various architectural applications. Renowned for its artistic design, this mesh combines functionality with elegance, making it a top choice for modern ...
Come From Hebei Qijie Wire Mesh MFG Co., Ltd.
Jayuan The cable conforms to the IEC Standard (EU) of EV Charging, which suits Electric Vehicles manufactured in European Countries. One end with sheath connects to the EV while The other end connects to the Charging Station. The other option is Cable Spiral Type, it saves more ...
Type2-Type1 EV Charging Cable The cable conforms to IEC & SAE Standard (EU & USA) of EV Charging, suits Electric Vehicles manufactured in European Countries and America. The Type 1 end (with sheath) connect to the EV while The Type 2 end connects to the Charging Station. The ...