Area (Nom.) sq. mm |
Number/size of Wire No./mm |
Insulation Thickness (Nom.) mm |
Sheath Thickness (Nom.) mm |
Width W (Approx) mm |
Thickness T (Approx) mm |
Resistance at 200C (Max.) ohm/Km |
Current carrying capacity at 400C Amps |
K3FL-2230 | 1.5 | 22/0.3 | 0.6 | 0.90 | 11.0 | 5.0 | 12.10 | 14 |
K3FL-3630 | 2.5 | 36/0.3 | 0.7 | 1.00 | 13.0 | 6.0 | 7.40 | 18 |
K3FL-5630 | 4.0 | 56/0.3 | 0.8 | 1.00 | 15.3 | 6.7 | 4.95 | 26 |
K3FL-8430 | 6.0 | 84/0.3 | 1.0 | 1.15 | 18.7 | 7.9 | 3.30 | 31 |
K3FL-14030 | 10.0 | 140/0.3 | 1.0 | 1.40 | 23.7 | 9.9 | 1.91 | 42 |
K3FL-22630 | 16.0 | 226/0.3 | 1.0 | 1.40 | 28.0 | 11.4 | 1.21 | 57 |
K3FL-35430 | 25.0 | 354/0.3 | 1.2 | 2.00 | 35.5 | 14.7 | 0.780 | 72 |
K3FL-49530 | 35.0 | 495/0.3 | 1.2 | 2.00 | 39.5 | 16.2 | 0.554 | 90 |
K3FL-70330 | 50.0 | 703/0.3 | 1.4 | 2.20 | 45.5 | 18.3 | 0.386 | 115 |
K3FL-36050 | 70.0 | 360/0.5 | 1.4 | 2.20 | 51.0 | 20.0 | 0.272 | 143 |
K3FL-47550 | 95.0 | 475/0.5 | 1.6 | 2.40 | 60.0 | 23.5 | 0.206 | 165 |
Basic Code |
Conductor Diameter (Nom) mm |
Thickness of Insulation (Min) mm |
Overall Diameter (Approx.) mm |
Conductor Resistance at 200C (Max) Ohms/Km |
KWS-0060 | 0.6 | 0.25 | 1.17 | 62.20 |
KWS-0070 | 0.7 | 0.30 | 1.37 | 45.70 |
KWS-0080 | 0.8 | 0.30 | 1.47 | 35.00 |
KWS-0090 | 0.9 | 0.30 | 1.57 | 27.60 |
KWS-0100 | 1.0 | 0.30 | 1.67 | 22.40 |
KWS-0110 | 1.1 | 0.30 | 1.77 | 18.50 |
KWS-0120 | 1.2 | 0.30 | 1.87 | 15.50 |
KWS-0130 | 1.3 | 0.30 | 1.97 | 13.20 |
KWS-0140 | 1.4 | 0.35 | 2.17 | 11.40 |
KWS-0150 | 1.5 | 0.35 | 2.27 | 9.95 |
KWS-0160 | 1.6 | 0.35 | 2.37 | 8.75 |
KWS-0170 | 1.7 | 0.35 | 2.47 | 7.75 |
KWS-0180 | 1.8 | 0.35 | 2.62 | 6.91 |
KWS-0190 | 1.9 | 0.35 | 2.72 | 6.20 |
KWS-0200 | 2.0 | 0.45 | 3.02 | 5.60 |
KWS-0210 | 2.1 | 0.45 | 3.12 | 5.08 |
KWS-0220 | 2.2 | 0.45 | 3.22 | 4.63 |
KWS-0230 | 2.3 | 0.45 | 3.32 | 4.23 |
KWS-0240 | 2.4 | 0.50 | 3.52 | 3.89 |
KWS-0250 | 2.5 | 0.50 | 3.62 | 3.58 |
KWS-0260 | 2.6 | 0.50 | 3.72 | 3.31 |
KWS-0270 | 2.7 | 0.50 | 3.82 | 3.07 |
KWS-0280 | 2.8 | 0.55 | 4.02 | 2.86 |
KWS-0290 | 2.9 | 0.55 | 4.12 | 2.66 |
KWS-0300 | 3.0 | 0.55 | 4.22 | 2.49 |
3 Core Flat Cables
HR PVC Insulated Winding Wires as per IS:8783 (Part 4/Sec I) 1995
Winding Wires / 3 Core Flat Cables for Submersible Pumps
try flat cable to get through more products
Winding Wires / 3 Core Flat Cables for Submersible Pumps |
CU/LSZH/lszh flat cable are the electric cables referred to thermosetting insulated and thermoplastic sheathed cables for voltage 450/750V electric power and lighting and having low emission of the smoke and corrosive gases when affected by the fire. 624-B refers to ...
The structure of flat fiber optic cable is to sheath single-mode or multi-mode optical fiber into a loose tube made of high modulus plastic, and the tube is filled with water blocking compound. The loose tube is covered with double-sided plastic coated (wrinkle) copper tape ...
The outstanding advantage of the multi hole cable gland is that the seal can have multiple outlet holes to meet the need of multi-harness cables. The seal has good toughness, can fix the cable, and make the cable gland to be waterproof and dustproof. Multi hole glands& Flat ...
Come From Zhejiang Saichuang Connector co.,ltd