Assembly:
1. Conductor copper, multiwire, round shaped, 5 class as per GOST 22483.
Conductors of cables intended for operation in tropical climate conditions are made of tinned/lead & tin alloy (tin contents not less than 40 %) clad copper wires.
2. Isolator polymer film, insulation can be applied without an isolator provided that the rubber does not stick.
3. Insulation insulating rubber.
Insulated conductors carry identification coloring either solid or in form of the longitudinal stripe. Neutral conductor insulation is blue. When there is no neutral conductor any conductor
insulation can be in blue except for the grounding one. Grounding conductor insulation is yellow-green and carries 0. Single or two conductor cable identification coloring is not specified. Red,
gray, white, green and yellow, if not combined, are not used for identification coloring of multiconductor cable conductors.
4. Twisting Insulated conductors are twisted with the lay length equal to not more than 16 diameters over cabling.
5. Isolator - polymer film, talcum or similar material are applied over the insulated conductors. It is possible to produce cores without film provided that the insulated conductors are separated
from the jacket.
6. Jacket - sheathing rubber, sheath thickness being given in.
For KG single conductor cables it is possible to replace both insulation and jacket with insulating and protective jacket. The nominal jacket thickness is equal to the sum of the nominal
thicknesses of insulation and jacket or double insulation thickness
Application:
These cables are intended for attaching movable gears to electric networks for 660 AV at frequencies of up to 400 Hz or 1000 CV with bending radius not less than 8 cable diameters at permissible
conductor heating temperatures of up to 750. Tropicalized cables have a T-extension added to the cable name with a hyphen. Cold resistant cables have a HL-extension added to the cable name with a
hyphen.
Technical details:
Type of climatization U, HL, , allocation category - 1,2 and3 as per GOST 15150-69.
Cables are resistant to changes of ambient temperature KG -400 to +500
KG-HL 600 to +500
KG-T 100 to +550
Cable construction length:
Nominal main conductor areas up to and including 35 mm2 at least..150 m
Nominal main conductor areas 50 to 120 mm2 at least...125 m
Nominal main conductor areas 150 mm2 and greater at least.100 m
(If agreed upon by a customer cables can be dispatched in any lengths.)
Cable guarantee service life6 months from the day of putting into operation but not later than 12 months from the manufacture
Service life of KG cables .. 4 years from the date of the cable manufacture
Tabulated data
OKP codes:
35 4441 01 KG cables
35 4441 23 KG-T cables
35 4441 17 KG-HL cables
KG, KG-HL TU 16. K73. 05-93
( Equivalent H07RN-F or KRANFLEX NSHTOU)
Supply Ability: | 130 Piece/Pieces per Month |
Minimum Order Quantity: | 5 Piece/Pieces cable drums |
Payment Terms: | L/C,D/A |
Port: | Saint-Petersburg, Russia |
Jacket: | PVC |
Conductor Material: | Aluminum |
Application: | Marine |
Type: | High Voltage |
Insulation Material: | PVC |
Model Number: | KG-HL TU 16.K73.05-93 |
Brand Name: | JSC Electrocable Works |
Place of Origin: | Russian Federation |
Type:Other Brand Name:V18 Place of Origin:Guangdong, China Model Number:PSK-7 power cable amplifier installation wiring kit ...
Come From Foshan Nanhai Bosheng Electronic Factory
Place of Origin:Guangdong, China Type:Other Brand Name:V18 Model Number:PSK-3 power cable amplifier installation wiring kit ...
Come From Foshan Nanhai Bosheng Electronic Factory
Brand Name:V18 Type:Other Place of Origin:Guangdong, China Model Number:PKG-66 Brand Name:V18 Place of Origin:Guangdong China (Mainland) 8 GA power cable amplifier installation wiring kit ...
Come From Foshan Nanhai Bosheng Electronic Factory