The OEM and customized products will also be welcomed!
3.4 being laid, the minimum temperature of the cable shall not be lower than zero degree. In the case of lower temperature, heating measures shall be taken.
3.3 no drop in limited provided there is full mechanical tention when cable is laid. It si forbidden to lay cable in iron-pipe or to fix cable by circling around the cable with iron materials.
3.2 the highest temperature of the conductor in short circuit (no longer than 5 seconds) in not more than 250 degrees, if a joint is in the cable, the temperature of the tinning welding joint is not more than 120 degrees, compressing joint not more than 150 degrees and electro-welding joint not more than 250 degrees.
3.1 long time operating temperature for cable conductor is 90 degrees.
3. cable's characteristic:
Laying conditions: for lyaing under ground with large different altitude, be able to bear external machanical force and moderate pulling force.
Laying conditions: for lyaing under ground with large different altitude, be able to bear external machanical force and moderate pulling force.
High voltage (35kv~220kv) copper or aluminium conductor/ xlpe insulation/ metal sheath (lead or corrugated aluminium)/ hdpe or pvc outer sheath power cable.
2.3 high voltage cable
1kv-35 kv multi-cores/ copper or aluminium conductor/ xlpe insulation / copper tape or copper wire screen / galvanized steel wire armored / pvc or pe sheath / power cable,
Voltage grade is up to 35kv, cross-section area can be up to 1000 sqmm (copper or aluminiun conductor). Conductor long-time operating temperature is 90 degrees. In short circuit, conductor highest temperature should be not more than 250 degrees.
2.2 medium voltage cabel
Low voltage (0.6/1 kv) single core or multi-core/ copper or aluminium conductor/ pvc inusulation/ steel tape armored or galvanized steel wire armored or unarmored/ pvc outer sheath power cable.
2.1 low voltage cable
2. voltage grade
1. the products are mainly complying with iec 60502 standard, also can be produced according to oem requirements and other standards, such as bs standard, din standard, astm standard, etc.
The fire retardant XLPE insulated power cable is copper or aluminum conductor.
The fire retardant xlpe insulated power cable, can be made complying with the IEC, BS, NFC STDS ETC. copper, aluminum conductor
try fire retardant to get through more products
Delivery Time: | Within 4 weeks or according to your request |
Package: | Wooden Drums, Steel-Wooden Drums, Steel Drums or according to your request! |
Supply Ability: | 500,000 Kilometer per Month |
Minimum Order Quantity: | 0.5 Kilometer |
Payment Terms: | L/C,T/T |
Port: | Qingdao, Shanghai or as your request |
Jacket: | PVC |
Conductor Material: | Copper |
Application: | Underground |
Type: | Medium Voltage |
Insulation Material: | XLPE |
Brand Name: | YIFANG |
Place of Origin: | Henan China (Mainland) |
ATP is able to quickly provide customers with High Flame Retardant cables material solutions that fully comply with the major building directives, safety codes, and environmental standards of the European Union(EN/EC), North America(UL/CSA), and China(GBT/JGB). ATP For ...
Come From GuangDong Advanced Thermoplastic Polymer Technology Co.,Ltd
Fire resistant power cable can maintain the integrity of the circuit and continue to work for a period of time when exposed to fire. The cables are also know as CU/MICA/PVC/PVC 0.6/1KV or CU/MICA/XLPE/PVC 0.6/1KV to basic standard IEC60502-1 or BS 7846. Layers of the mica tape ...
Fire resistant control cable 2-4 cores 300/500V features Mica tape twisted with copper conductor, the cable refers as multiple cores Cu/MicaXLPE(PVC)/LSZH 300/500V to basic standard BS7211. The function of mica is to prevent burning when cables catching fire. The cable can ...