Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent
hysteresis loss factor for 1 and 3 layer constructions.
Notes:
ACSR bare conductor meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)
Specifications:
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad
(AW). Additional corrosion protection is available through the application of grease to the corer or infusion of the complete cable with grease.
Construction:
Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be
achieved without sacrificing ampacity.
Applications:
ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power.
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also
can be satisfied.
AAC(All aluminum conductor) are suited for overhead power line.
All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM (AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191
3). Application: ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels.
2). Specification: ACSR is composed by bare concentric-lay-stranded galvanized steel wire(s) with aluminum wires surrounded by one or more layers of helically. Greased ACSR can also be supplied.
1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182.
2. Elative manufacturing standards: IEC83, IEC1089, 31, B232, BS215, DIN48204.
(7)aluminimum conductor aluminimum alloy reinforced(ACAR)
(6)rear earth aluminimum conductor steel reinforced(ACSR/RE)
(2) all aluminimum alloy conductor(AAAC)
(3) aluminum conductor steel reinforced (ACSR)
(4) anti-corrosion type ACSR
(5) aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)
(1) all aluminium conductor (AAC)
1. Specification:
Since they have such good characteristics as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity and are also suitable for laying across rivers and valleys where special geographical teatures exist.
AAC,AAAC,ACSR,ASCSR&ACAR conductor widely used in power transmission lines with various voltage levels.
AAC,AAAC,ACSR,ASCSR&ACAR conductor widely used in power transmission lines with various voltage levels.
Delivery Time: | 30 working days |
Package: | in drums. |
Supply Ability: | 50,000 Ton per Year |
Minimum Order Quantity: | 20 Ton |
Payment Terms: | L/C,T/T,Western Union |
Jacket: | without |
Conductor Material: | Aluminum |
Application: | Power Station |
Type: | High Voltage |
Model Number: | AAC&AAAC&ACSR&AACSR*ACAR |
Brand Name: | HNTDDL |
Place of Origin: | Henan China (Mainland) |
Steel - cored aluminium stranded wire, it could also be described as ACSR Conductor or ACSR Aluminium Conductor or acsr goat conductor steel reinforced etc.. Steel - cored aluminium stranded wire has the same structure as the aluminum conductor alloy reinforced (ACAR) , except ...
Come From HENAN HONREY CABLE CO.,LTD
Aluminum clad steel core aluminum stranded wire is mainly used for overhead lines, compared with ordinary steel core aluminum stranded wire, with light weight, high load, low power loss and other advantages, and anti-corrosion performance, erection and maintenance is ...
Come From HENAN HONREY CABLE CO.,LTD
Steel core aluminum alloy stranded wire is mainly used in long-span overhead transmission lines, with good tensile strength. The aacsr conductor is widely used in high-altitude heavy ice lines and UHV smart power grids. In addition, the anticorrosive steel core aluminum alloy ...
Come From HENAN HONREY CABLE CO.,LTD