KIRLOSKAR/VIVEKANAND / ARGO make transformers are widely used by electricity boards, power distribution houses, textile mills, paper plants, chemical plants, pharmaceutical industries, automobile industries, railways, public sector under takings & various other industries, organisations. CORES:The core is made of imported C.R.G.O. silicon steel laminations with both sides carlite insulation of M4 grade to minimise iron losses & magnetising current. To achieve a minimum sound level (humming noise) , the clamping device is so designed as to give a force evenly distributed on the magnetic core. WINDINGS:High voltage & low voltage windings are of different types like spiral, helical, crossover or continuous disc. The windings are of electrolytic copper round wires & strips insulated with paper of class "A" insulation. INSULATION:All insulation materials used are from PLEPHANTIDE? press boards & of permawood wherever necessary. TAPPING SWITCH:Manually operated off circuit tapping switch is provided for different plus minus voltage variations with lock & key arrangement. The contacts of switch are of copper& tin-plated to ensure sparkless , trouble free & smooth operations. The transformers can also be provided with ON LOAD TAP CHANGER if customers so require, at an extra cost. OIL:Transformers are supplied with first filling of high quality oil conforming to the IS :335 for better insulation & cooling. TANK:Tank is made of high quality C.R.C.A. M.S. sheets with sufficient stiffeners & all other standard accessories , like conservator, rollers, cooling radiators, drain valve, filter valve etc. Tank is welded from inside and outside & pressure tested at 7 lb/in2 to make it leakproof. FINISHING:The outer tank surfaces of transformer are primarily coated with two coats of red primer followed by three coats of light gray paint as per the IS :5 shade no. 631. The inside of the tank surfaces are painted by applying oil resistant zinc chrome paint. TESTS:All transformers are manufactured & thorough routine tests are conducted as per IS: 2026 GUARANTEE:All transformers are guaranteed for a period of 24 months against any design / manufacturing defects. TERMINAL ARRANGEMENTS: 1) H.V. bare bushing or cable box2) L.V. cable box or bus duct. STANDARD FITTINGS: * Rating & diagram plate* Bi-directional rollers* Silica ?gel breather * Explosion Vent* Thermometer pocket * Air release plug* Conservator with drain plug * Oil level gauge* tapping switch ( off circuit) with lock/key arrangement. * Top filter valve* Bottom filter valve cum drain valve* Additional neutral bushing.* Earthing pads , lifting lugs & inspection cover * Oil sampling Valve. EXTRA FITTINGS: * Buchholz relay with alarm & trip contact * Stem-type oil temperature indicator * Dial type oil temperature indicator with alarm * Dial type winding temperature indicator & trip contact. With C.T. with alarm & trip contact* Dial type oil magnetic oil level gauge with low * Marshalling box ( weather Yroof) level alarm contact.* isolating radiator valves* Jacking pads * neutral current transformer. RANGE OF PRODUCTS: Transformers:Control, L.T. Power, Furnace, Rectifier, Motor starting, Scott ?connected, Three Phase to Single Phase , Neon sign, Ignition, High Voltage Low Current, Low Voltage High Current, Single Winding, Multi-shielded, Ultra Isolation & special transformers. Distribution Transformers, Reactors, Ballast & Filter Chokes Continuously variable voltage autotransformers ( Autostat):Single, two & three phase models, air cooled/ oil cooled , manual / motorised 1 to 600 amps. Voltage Stabilisers:Manual A.C. Voltage Stabiliser in single & three phase models with stepped or smooth controls. Servo controlled A.C. Voltage Stabilisers:Single , two & three phase models upto 1,000 KVA. Solid state A.C. Voltage Stabilisers:Single & three phase models. Ferro ?resonant-type constant voltage transformers (CVT):Automatic line voltage corrector ( Relay type) Rectifiers:Battery charging ( boost / float), Electro-plating, anodising , hydrogenation & for other electrochemical processes. Automatic constant current / constant voltage rectifiers:In single & three phase models D.C. motor drives:For traction, etc. Test kits:A.C. high voltage break down tester, primary & secondary injection sets. Special electronics equipments Uninterruptible Power Supply (UPS) Systems (ONLINE / OFF-LINE) Investors, Power Supplies etc. REFERENCE PRICE LIST FOR TRANSFORMERS UPTO 3150 KVA. ALUMINIUM WOUND TRANSFORMERS Sr. No. KVA Capacity Voltage Ratio (V) Price each (Rs.) 1 160 11000/433V 1,07,000/- 2 200 11000/433V 1,22,500/- 3 250 11000/433V 1,42,500/- COPPER WOUND TRANSFORMERS Sr. No. KVA Capacity Voltage Ratio (V) Price each (Rs.) 4 315 11000/433 1,99,000/- 5 400 11000/433 2,24,000/- 6 500 11000/433 2,66,000/- 7 500 22000/433 2,85,000/- 8 500 33000/433 3,13,000/- 9 630 11000/433 3,07,000/- 10 630 22000/433 3,24,000/- 11 630 33000/433 3,64,000/- 12 800 11000/433 4,02,000/- 13 800 22000/433 4,12,000/- 14 800 33000/433 4,24,000/- 15 1000 11000/433 4,44,000/- 16 1000 22000/433 4,53,000/- 17 1000 33000/433 4,68,500/- 18 1250 11000/433 5,24,000/- 19 1250 22000/433 5,36,500/- 20 1250 33000/433 5,61,500/- 21 1600 11000/433 6,27,000/- 22 1600 22000/433 6,85,000/- 23 1600 33000/433 7,00,000/- 24 2000 11000/433 7,34,500/- 25 2000 22000/433 8,11,000/- 26 2000 33000/433 8,67,500/- 27 2500 11000/433 8,85,000/- 28 2500 22000/433 9,93,000/- 29 2500 33000/433 1,067,000/- 30 3000 11000/433 1,148,500/- 31 3000 22000/433 1,206,000/- 32 3000 33000/433 1,220,000/- 33 3150 11000/433 1,206,000/- 34 3150 22000/433 1,265,000/- 35 3150 33000/433 1,286,000/-
POWER DISTRIBUTION & FURNACE TRANSFORMERS |