Oil Filled Current Transformers

Current transformers are tested in fully equipped testing lab for all routine tests as per IS : 2705, I IEC6004-part 1or other relevant standard as specified by the customer. The CTs are also tested at CPRI for various rating from time to time in approved labs for design validation.
 

TESTING

All Current transformers have special identification number given right from stage one. This will enable us to trace the fault up to root level in case of failures and thus implement the preventive action.

Secondary winding is made first over the toroid with thermal isolation. Insulation of the secondary winding is done in accordance with high voltage requirements. Primary is finally wound over the insulated coil. Surface of the coil is made uni-potential with special tapes. Number of such uni-potential layer depend upon the system voltage. Such layers will relieve the coil from voltage stresses. Secondary leads are brought to the terminal box through the insulator. The complete coil assembly is then placed in the tank and gently slipped inside the vacuum heating and drying ovens to completely dehydrate the equipment and ensure long operating life.

Construction

 

  • Country:Pakistan
  • telephone:92-21-4234144
Oil Filled current transformers in high voltage applications are still the preferred
*Your name:
*Your Email:
*To:skipper
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters Remaining: 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

We do inquire for you , please wait ...

Split Core Current Transformer

Split Core Current Transformer The appearance is nice and the installation and wiring are convenient. AKH-0.66/K-Φ series split type ct transformers are mainly used in reconstructing projects of urban and rural power grids. Product has the advantages of small size, high ...

Come From Acrel Co.,Ltd.

Current transformer clamp for large current

The model Q150 current transformer clamp can be used in large current situation and cooperate to cable fault tester and cable identification device, used for cable test work. It can even measure up to 3000A AC large current and output 0-5A AC current for other measuring or ...

Come From gfuvegroup

ACREL AKH-0.66 / K SPLIT CORE CURRENT TRANSFORMER

Acrel AKH-0.66/K series current transformer split core are mainly used in reconstructing projects of urban and rural power grids. The split core current sensors can be mounted easily without the removal of the primary bus. They also can be operated with electricity, which ...

Come From Jiangsu Acrel Electrical Manufacturing Co., LTD.1