NOTE: Please see latest sample brochures and outline drawings for detail technical specification.
SZ10 series35kV three-phase double-winding load tap changer power transformer.
S10 series 35kV three-phase double-winding off-load tap changer power transformer.
Technical parameters
Tank
Tanks structures are bell type and barrel type. The plates are curved to corrugated wall. Our tanks are good aesthetic, compact and high ability of mechanical strength. Avoiding leakage, there are
fine machining flanges in key connection parts (bushings, pressure valves, switches etc.)
Windings
HV winding is continuous model while LV winding is continuous or screwy model. And regulation windings are separate, so turns are even and mechanism power are minimized??HV and LV windings use
construction of conductor of oil which makes oil oriented, so oil stream will move heat away.
Active Part
Bringing board construction is adopted. In order to strengthen ability of withstand short-circuit, we nail some pressure nails around pressure board and use support beam to connect HV and LV claps
to make cores a whole. Otherwise, we paint special plastic to surface of core pole to make the silicon steel sheets link. After solidification, core sheets are a whole body so they can reduce noise
and increase mechanical strength and prevent rust. Underside active part support wall of tank with strong electric pressure board in order to make underside active part fixed safely.
Core
The core sheets are cut by the step-lap core lamination line from GEORG Co. of Germany. They are step-lapping which ensures a particularly favorable magnetic flux distribution at the joints.
No-load loss, no-load current and noise are minimized.
Structure and construction features
Insulation level: Power frequency voltage withstand: AC-85kV, impulse withstand voltage: LI-200kV
Type of cooling: ONAN, ONAF
Service Condition: According to customers?? requirements
Impedance Voltage: According to customers?? requirements
Vector Group: Yd11, Ynd11, Dy11, Dyn11, Ynyn0d11
Phase No.: three phases
Frequency: 50Hz, 60Hz
Power Capacity: 40000kVA and below
Model of voltage regulation: excitation voltage regulation (OLTC), off-excitation voltage regulation
Voltage level: 35kV
Technical Specification
Voltage level: 35kV Model of voltage regulation: excitation voltage regulation (OLTC), off-excitation voltage regulation |
At Viva Marketing, we are passionate experts dedicated to enhancing brand visibility and impact. We provide innovative, tailor-made solutions to propel your business to new heights. Whether you\'re looking to boost your online presence, optimize social media engagement, or ...
Come From viva-marketing.agency
Split Core Current Transformer The appearance is nice and the installation and wiring are convenient. AKH-0.66/K-Φ series split type ct transformers are mainly used in reconstructing projects of urban and rural power grids. Product has the advantages of small size, high ...
Come From Acrel Co.,Ltd.
Elevate your interior design with WallWrap, a game-changingdigital ...
Come From Power Graphics Digital Imaging, Inc