Features: 1) Power supply: 220 VAC / 380VAC + -20% , 50Hz. 2) Operating current: 5A, 100mA to 6A3) Settings range: 0. 85 to 1 (inductive) , Current transformer ratio: 25-2, 500 / 54) Accuracy: class 2% + -1 digit. 5) Connection type: terminals6) Power consumption: <1W. 7) Type: balanced compensation up to 3 phases, 4 wires. 8) Step Count: 6 steps, 12 steps. 9) Output contacts: 6, 12@8A, 1750VA. 10) Time delay: progarmmable11) Operating range: -5 to + 55C12) Storage range: -25 to + 70C13) Relative humidity: 95% 14) Protection class: IP20 (for front panel) 15) Equipment protection: double insulation16) Switchboard cutout: 139 x 139mm17) Installation: flush-mounting with rear terminals18) Weight: 0. 8kg19) 8 Setting modes: A) Setting the target PF: In this mode the user can set a target PF that the PFC will regulate the actual PF to. B) Setting the Delay time: In this mode the user can set a delay time between consecutive application of steps. C) Setting the number of effective steps: In this mode the user can set an effective number of steps, disabling the higher steps from operation. D) Setting the THD threshold: In this mode the user can set a THD threshold that when the voltage or current exceeds a warning is issued. E) Setting the CT Primary current: In this mode the user can set the Primary current of the used current transformer whilst the secondary current is by default 5 A. F) Viewing capacitor values: In this mode, the user can check the values of various capacitor used in every step. And change this value if desiredG) Viewing number of switches for each step: In this mode, the user can view the number of switches made by each step. H) The value determination program: In this mode, a special program is run to automatically determine the value of the capacitor for each step.
Features:
1) Power supply: 220 VAC / 380VAC + -20% , 50Hz.
2) Operating current: 5A, 100mA to 6A
Application: | Power |
Model Number: | smart06-a, smart12-a |
We at CCS can provide customers with a variety of electrical transmission equipment and electrical control solutions, which can meet the needs of various working conditions. We strictly control the quality, from raw material procurement to factory test, and all is in accordance ...
Come From Qingdao CCS Electric Corporation
Fire Alarm Controller for Energy Storage Power Station The Fire alarm controller is set in each energy storage cabin, with alarm signal acquisition with the cabin detector, start the Fire extinguishing device, linkage alarm, linkage communication with BMS and other functions. ...
Come From Sichuan Xuxin Technology Co., LTD
The BL120 is an industrial Ethernet gateway with 2 Ethernet ports and 2 RS-232/485 serial port. BLIIoT BL120 gateway supports Modbus RTU/Modbus TCP to Modbus TCP industrial protocols conversion. The Modbus RTU to Modbus TCP Gateway usually required when metering devices using ...
Come From BLIIOT