Pressure Range 0 to 4 to 0 to 200mwg (mA & V)
0 to 10, 20, 50,100, 200mwg (mV)
Proof Pressure 1.5 x Fs nominal range
Burst Pressure 3 x Fs
Fatigue Life Designed for more than 100 million FS cycles
Performance
Long Term Drift 0.2% FS/year (non-cumulative)
Accuracy 0.25% FS typical
Thermal Error 0.5% Typical 0-50
Immersible pressure/level transducer has been specifically
designed to met the rigours of long term immersibility
Delivery Time: | 3-4 weeks |
Minimum Order Quantity: | 1 Set/Sets |
Payment Terms: | T/T |
Model Number: | 2200, 2400, 2600 |
Protection Level: | IP67 |
Output: | Analog Sensor |
Theory: | Submersible |
Usage: | Level Sensor |
Model Number: | 2200 2400 2600 |
Brand Name: | Gems |
Place of Origin: | United States |