Voltage Transducer - BW-34

(Per WH or VarH)

1~1000 Pulse

(Pulse Output)

4~20mA
0~5mA
0~20mA
0~10mA
0~1mA
-1~0~+1mA

Current Output

0~100mV
0~1V
0~10V
0~5V
1~5V
-1~0~+1V


Specifications

 

  • Country:Taiwan
  • telephone:886-2-27206601
Max.Input AC 600V, 5A
*Your name:
*Your Email:
*To:Maxthermo-Gitta Group Corp.
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters Remaining: 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

We do inquire for you , please wait ...

DC Voltage Transducer

Using linear photoelectric isolation measuring principle. Terminal connecting input. High accuracy with low temperature drift. Linear measuring range: 0 ~ 120% of nominal input. Input impedance: When VX≤ 1V, Ri≥ 50kΩ; When VX≥ 1V, Ri≥ Vx× 10kΩ/V Isolation: >1 KV DC/ ...

Come From SAIS CO.,LTD.

High Voltage 12KV Switchgear Epoxy Resin Transducer/Sensor/Insolator

Features : 12kv High voltage Epoxy resin casting switchgear sensor adopting epoxy vacuum pouring for one-time molding,surface is smooth and leveling without any burnishing,mending or lacquering,bright colored,withstand voltage insulation performance is high and partial ...

Come From Wenzhou Zeen Electric Co.,Ltd

True RMS Voltage Transducer

Our range of True RMS Current and Voltage transducers provide a convenient way of converting commonly found AC currents and voltages to useful process signal levels. A high quality RMS to DC converter and precision current shunt or voltage divider forms the input stage capable ...

Come From danntech

Voltage Transducer - BF-1

(Per WH or VarH) 1~1000 Pulse (Pulse Output) 4~20mA 0~5mA 0~20mA 0~10mA 0~1mA -1~0~+1mA Current Output Transducer Model AC Input Rated Output Accuracy AC Voltage ...

Come From Maxthermo-Gitta Group Corp.

DC voltage 20 mV...11.9V input 4kV isolation Transducer

DC voltage 20 mV...11.9V input 4kV isolation These isolators isolate the DC input signal from the DC Output signal, which is directly proportional to the input signal. There are two levels of isolation offered, the M100-DA1 / DV1 / DV2 have 4kV isolation and the M100-DA1I / ...

Come From HOYT ELECTRICAL INSTRUMENT WORKS INC

Voltage Transducer - BV-3

(Per WH or VarH) 1~1000 Pulse (Pulse Output) 4~20mA 0~5mA 0~20mA 0~10mA 0~1mA -1~0~+1mA Current Output 0~100mV 0~1V 0~10V 0~5V 1~5V -1~0~+1V ABS Plastic (The case can be mounted on a 35mm rail which complies with Din 46277) Specifications ...

Come From Maxthermo-Gitta Group Corp.

Sell 1 Element AC Analog Voltage Transducer / sensor

Response time:2500ms Power source: +12v or +15v or +24v Load capability: Voltage output >2000 ohm Current output <250 ohm Quiscent power consumption: =250mw Product:1 element AC analog voltage transducer Series: Ce-vj03 Ce-vj03a(true rms) Input range:10v~1000v Output:5v or 4-20 ...

Come From Shenzhen Sensor Electronic Technology Co., Ltd

Current and Voltage Transducers

Technical Product Information Input Signal Range 0-5A AC Frequency 40..70 Hz Wave Type Sinus Do?rusal ...

Come From KLEMSAN ELEKTRIK ELEKTRONIK SAN.VE TIC.A.S.