Calibration:
The sensor comes pre calibrated from the factory. The sensor may be recalibrated in the field.
Follow the steps below to recalibrate.
1. Sensor alignment must be done before calibration.
2. P1 must be adjusted first.
3. Place the target at the near distance (closest distance target will get to sensor). Measure the distance from the target to the transducer face (DO NOT TOUCH THE FACE OF THE TRANSDUCER).
4. Calculate the voltage for the near distance. Multiply the distance by the volts per inch. Adjust P1 for the calculated voltage.
5. Place the target at the far distance (farthest distance target will be from sensor). Measure the distance from the target to the transducer face.
6. Calculate the voltage for the far distance. Multiply the distance by the volts per inch. Adjust P2 for the calculated voltage.
7. Repeat the adjustment of P1 and P2 to check for accuracy.
Sensor Alignment:
The sensor must be aligned to obtain the best accuracy. To align the sensor place the target you will be measuring at the farthest distance it will be from the sensor. Monitor the color of the LED
on the sensor (green is no signal, light red is a weak signal, and bright red is a strong signal) align the sensor, so the LED is the brightest red color you can get. This will be the optimum
alignment of the sensor.
SENSOR SETUP
Air Temperature:
The air temperature between the sensor and target must be constant. Any variations in air temperature will compromise the accuracy. The sensor can compensate for changes in air temperature provided
the air temperature is constant between the sensor and target. If the air temperature varies between the sensor and target (For example if the air temperature is 20 from the sensor face to half way
to the target, and the air temperature is 25 for the remainder of the distance) the sensor cannot compensate for the temperature variation.
Weight: 22 oz. (shipping weight 3 lbs.)
Update Time: 2s Maximum
Sample Rate: 20ms Typical
Housing Material: Stainless Steel with PVC Head
Frequency: 60kHz
Load 500 Ohms to Infinity
Output Referenced to Power GND or Signal GND
Short Circuit Protected
Output: Analog Voltage Output
Operating Temperature: 0 to 50
Input Current: 65mA Typical
Power Input: 20 to 30VDC Reverse Polarity Protected
The RPS-412A is designed to take advantage of today's PLC and computer analog input cards. The analog input card will determine the resolution of the system. The numerical values programmed into the PLC or computer will determine the zero and span.
The RPS-412A has a 0-10V analog output. The analog output is fixed. The RPS-412A-16 is 0.625V per inch. The RPS-412A-10 is 1.000V per inch. For example using the 3-16" range version, a target placed 3 inches from the sensor face will result in a sensor output of 1.875V. A target placed 16 inches from the sensor face will result in a sensor output of 10.0V.
The RPS-412A has a 47mm stainless steel barrel housing. The stainless steel housing is electrically isolated from the sensor electronics. The sensor comes with two jam nuts for mounting.
The RPS-412A is a high accuracy analog ultrasonic sensor (?.002" or 0.05% of range, which ever is greater, at 25). The sensor has a built in temperature compensation target, that monitors and compensates for air temperature 50 times per second. The sensor also compensates for changes in relative humidity, changes in barometric pressure, and other factors that influence the speed of sound.
Features |
High Accuracy Digital Thermometer shecare high accuracy digital thermometer also known as high precision digital thermometer lasts for more than 16-20 days. This is a non-Bluetooth basic thermometer. Please manually enter the basal body temperature value into the App. This kind ...
Come From Shecare-ikangtai
High Accuracy Pressure Transmitter LFT2010 High accuracy pressure transmitter applies a silicon strain diaphragm embedded in an oil-filled steel housing and the repeatable & low hysteresis properties of silicon are exploited by the difference normalization digital amplifier to ...
Come From LEFOO INDUSTRIAL CO.,LTD.
HT (260℃) High Temperature Fiber Optic Connector Sensor High temperature resistant connector uses special fiber with high temperature survivable coating and special epoxy, which makes it resistant for 260°C and reflowable as well. HT(260℃)Connector Feature Fiber Type: ...
Come From Zhongshan Meisu Technolody Co.,Ltd