The 200136 SLD transducer incorporates highly reliable proximity probe technology observing a moving diaphragm to detect static pressure changes on the non-pressurized end of single or double seals or between tandem or dual seals. Changes in pressure indicate failing seals. The transducer is specifically designed for use with our 200135 TIM as part of a Trendmaster? Pro system for continuous monitoring of process pumps handling toxic or flammable materials in the chemical and hydrocarbon processing industries.
The 200136 SLD transducer incorporates highly reliable proximity probe technology |