SAMPLING TRANSFORMER OIL

                                                                                                  

Oil samples can be taken at any time from most equipment without having to take it out of service, allowing a window inside the electrical apparatus that helps with diagnosing and troubleshooting potential problems.                   

PCBs are poisoness, which have been shown to cause damage to the reproductive, neurological and immune system of wildlife and humans, thus where explosions of transformers takes place it can cause costly decontamination work.

PCBs are a group of synthetic oil-liked chemicals of the organ chlorine family.  Until their toxic nature was recognized and their use was banned in the early 1980s, they were widely used as insulation in electrical equipment and particularly in transformers

PCB Analysis (PCB Test)

 

Dissolved gas-in-oil analysis has become a standard in the electrical maintenance industry throughout the world and is considered to be the most important oil test for transformer oil in electrical apparatus.  As the insulating materials of a transformer breakdown from excessive thermal or electrical stress, gaseous by- products form. The by-products are characteristics of the type of incipient fault conditions, the materials involved and the severity of the condition. Dissolved gases are detectable in low concentrations (ppm level), which usually permits early intervention before failure of the electrical apparatus occurs, and allows for planned maintenance.  Dissolved Gas Analysis is used not only as a diagnostic tool but also stem apparatus failure. 

Dissolved Gas Analysis (Gas Test)

 

Dielectric strength of transformer oil is a measure of the oils ability to withstand electrical stress without failure.  Transformer oils are designed to provide electrical insulation under high electrical potentials, any significant reduction in the dielectric strength will indicate that the oil is no longer able to perform this vital function.  Some of the things that can cause a reduction in dielectric strength include contaminants such as water, sediment, conducting particles, oil degradation by-products and cellulose paper breakdown.

Dielectric Strength (KV-Test)

 

Transformer oils are oxidized under the influence of excessive temperature and oxygen, particularly in the presence of small metal particles which can act as catalyst. Oxidation products are usually acidic in nature and result in an increase in acid number.  Further reaction of these acids with the bulk oil can result in sludge and varnish deposits.  In the worst-case scenario, the oil canals can become blocked and the transformer is not cooled down adequately, which further exacerbates oil breakdown.  Increase in the acidity has a damaging effect on the cellulose paper.  Thus goes hand in hand with a decrease in dielectric strength and increased moisture content.

Acid Test (Acid Test)

 

One of the most important functions of transformer oil is to provide electrical insulation. Any increase in moisture content can reduce the insulating properties of the oil, which may result in dielectric breakdown. Water and oil due to their differing chemical properties are not mutually soluble.  However up to a certain limit a small amount of water will dissolve in the oil.  With fluctuating temperatures the dissolved water will become free as the transformer cools down, resulting in poor insulating power and oil degradation. Many transformers contain cellulose-based paper, which is used as insulation in the windings. Excessive moisture content can result in the breakdown of this paper insulation with a resultant loss in performance. The test performed is of extreme sensitivity and can detect water at levels down to a few part per million

Moisture content (PPM Test )                  

 

   SAMPLING ON TRANSFORMERS  

TRANSFORMER OIL SAMPLING

  • Coil Number:ANY
  • Coil Structure:ANY
  • Phase:ANY
  • Usage:ANY
  • Model Number:ANY
  • Brand Name:ANY
  • Place of Origin:South Africa
  • Country:South Africa
  • telephone:27-017-6380081
Coil Number: ANY
Coil Structure: ANY
Phase: ANY
Usage: ANY
Model Number: ANY
Brand Name: ANY
Place of Origin: South Africa
*Your name:
*Your Email:
*To:SWITCHGEAR
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters Remaining: 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

We do inquire for you , please wait ...

PMK oil and powder in stock free sample

pmk 粉末、 PMK 油品在线销售 在线购买 PMK 乙基甘氨酸酯油,无需处方, ...

Come From www.ukcompany.com

EU Warehouse Free Sample USA Mexico Canada Netherland CAS 20320-59-6 New BMK Pmk Oil Powder 28578-16-7

Packaging & Shipping Liquid → → → 1L / Bottle, 25L/drum (5L, 10L all available) Powder → → → 1L/ plastic bag, 25KG/drum (5kg, 10kg all available) Basically, our product MOQ is 1KG/1L for testing. Bulk price is much cheaper, due to 1L/1kg shipping fee is high. ...

Come From Wuhan Chuanglang New Materials Co., LTD

Oil Immersed Transformer

As one of the professional oil filled transformer manufacturers, our oil immersed power transformer is specially developed and designed based on the advanced technology abroad for rough mountainous topography and transportation difficulties to meet the requirement of China oil ...

Come From Shaanxi Hanzhong Transformer Co., ltd