Pipe circulation : When outlet pipe temperature is lower than setting data ,pipe circulation pump P2 will start to inject hot water of the tank into the tank ,make sure that when you open the water tap you will have hot water .
Electrical heater assistant : When water temperature in the tank is below the setting data at the setting time the electrical heater will start to heat water till reach the setting data .
Anti-freezing circulation : When circulation pipe temperature is lower than setting data ,temperature difference pump will start to inject hot water from tank to the circulation pipe, When the circulation pipe temperature is higher than setting data ,the pump will stop .
Temperature difference circulation: When solar collector temperature is 10oC higher than tank temperature ,circulation pump P1 will start to inject cold water from tank to the collectors ,so hot water in the collectors will go to the tank ,When temperature difference is lower than 3oC circulation pump will stop .
Auto charging water : Charging water by solenoid valve. When reach the setting time and setting water level ,the solenoid valve will start to charge water till the tank is full of water
Principles and characteristics:
*This model got solar keymark from Germany TUV
45
112
90
3.9
58
Sunshore is the only supplier in China who got non pressure solar collector with solar keymark.
high quality
low cost
Delivery Time: | within 30 days |
Package: | cartons |
Supply Ability: | 1000 Set/Sets per Week |
Minimum Order Quantity: | 2 Set/Sets |
Payment Terms: | L/C,T/T |
Port: | shanghai |
Pipe Material: | Glass |
Application: | Water Heater |
Type: | Vacuum Solar Collector |
Brand Name: | Sunshore |
Place of Origin: | Jiangsu China (Mainland) |
Type:Evacuated Tube Pressure:Unpressurized Circulation Type:Direct / Open Loop (Active) Heating System:Thermosyphon (Passive) Connection Type:Direct-Plug Installation:Freestanding Housing Material:Galvanized Steel Certification:CE, ISO9001,3C Capacity:150~360 Place of ...
Come From Haining Bangni New Energy Co.Ltd
Non pressurized solar collector SPCF Non Pressure Solar Collector (SPCF-58 / 1800) Low Pressur Solar Keymark Mexico Model NO.:SPCF-58/1800-60 Application:Water Heater Capacity: 50-300l Trademark:Sunpower or OEM Origin: China Type: Non-Pressure Pipe Material:Glass Solar Water ...
This solar water heater has passed SRCC, CE, ISO9001: 2000, CCC, solar Keymark, SABS and other certification. The features of solar water heater: 1) Outer tank material: SUS304 2B stainless steel plate or Colour steel. 2) Inner tank material: SUS304 BA food grade stainless steel ...