After over discharged, the controller will resume to work while you press the power switch, note the battery voltage needs to be over 12.6V.
2. After over discharged, the controller will resume to work when the battery is charged to 12.6V. (for 12V system only, for 24v, use 2X)
controller will resume to work after 30 seconds.
1. the output will cut off once there is over load or short circuit. Press the power switch, the
Please note:
Red blink when the load is short-circuit.
amps is 1.5 times of rated current for 5 seconds)
(the load amps is 1.25 times of rated current for 60 seconds, or the load
Red slowly flashing when its over load
Red ON when the output is on.
Red ON when loads cut off
Yellow ON when battery level low
Green slowly flashing when battery level full
Green ON when battery level in the right range
..
Green blink when the system over voltage
Green ON when solar is charging battery
LED INDICATOR
10 minutes off before the controller start to work.
The controller requires 10 minutes of continuous transition values before it starts to work. These constraints avoid false transitions due to lightning or dark storm clouds.
Press the power switch for 5 seconds, and select the desired LIGHTING CONTROL option. The LED is on, which confirmed you have selected the right one.
LIGHTING CONTROL OPTIONS
7. Press the BUTTON 0 or 9 to verify the system connecting.
6. Connect the LIGHT last. If the red LED indicator lights, the battery capacity is low and should be charged before completing the system installation
5. Connect the SOLAR(PV array) next. The green LED indicator will light if sunlight is present.
4. Connect the BATTERY first. Use care that bare wires do not touch the metal case of the controller.
l Use with 12V or 24V systems only
l Use with 12V or 24V batteries only
3. It is recommended that the connections be made in order from 1 to 6. (see the following picture)
2. Make sure the PV and load currents will not exceed the ratings of the controller being installed.
1. Mount the controller to a vertical surface. Allow space above and below the controller for air flow.
This section provides a brief overview of how to get started using the controller. However, please review the entire manual to ensure best performance and years of trouble-free service.
QUICK START INSTRUCTIONS
Temperature: -35 to +55
Temp Comp.(mV/) -30mV -60mV
Float voltage 13.6v 27.2v
Boost voltage(10 minutes) 14.4v 28.8v
Equalization voltage(10 minutes) 14.6v 29.2v
Load reconnect 12.6V 25.20V
Load disconnect 11.1V 22.2V
25% Current overload 1 min. 1 min.
Rated load 5/10A 5/10A
Rated solar input 5/10A 5/10A
12Volt 24Volt
TECHNICAL INFORMATION
NOTES: For use with solar panels only
EPRC-MT-10 12V or 12/24V auto-work, 10Amp
EPRC-MT-5, 12V or 12/24V auto-work, 5Amp
RATINGS (12V or 12/24V auto work)
EPRC-ST-MT series
solar charge controller,
INSTRUCTION MANUAL
TECHNICAL INFORMATION
12Volt 24Volt
Rated solar input 5/10A
Maximum Current: | 5000 |
Rated Voltage: | 12/24V AUTO |
Application: | Solar System Controller |
Model Number: | 20 |
Brand Name: | OEM |
Place of Origin: | China (Mainland) |
1. The size of this control box refers to the following dimensions; 2. The control box contains a DC circuit breaker; 3. The incoming and outgoing lines are wired with standard aviation plugs. Features of KE300D-03-01 Solar inverter control pump Excellent cooling performance ...
Come From Shenzhen MICNO Electric Co., Ltd.
The Cosuper Inverter LPT2000 integrates the function of battery inverter, battery charger and automatic transfer switch into a single unit, which helps save space and simplify installation by reducing the amount of equipment and cables installed, making it suitable for use in ...
All series of iPandee MPPT solar charging controllers incorporate new design concepts, keep up with the development of science and technology, adapt to the needs of cutting-edge off-grid system applications, and adopt our own patented MPPT control algorithm technology, which ...