MT-10 solar charge controller

After over discharged, the controller will resume to work while you press the power switch, note the battery voltage needs to be over 12.6V.

2.      After over discharged, the controller will resume to work when the battery is charged to 12.6V. (for 12V system only, for 24v, use 2X)

controller will resume to work after 30 seconds.

1.      the output will cut off once there is over load or short circuit. Press the power switch, the

Please note:

                 Red blink when the load is short-circuit.

amps is 1.5 times of rated current for 5 seconds)

(the load amps is 1.25 times of rated current for 60 seconds, or the load   

       Red slowly flashing when its over load

       Red ON when the output is on.

                    Red ON when loads cut off

        Yellow ON when battery level low

        Green slowly flashing when battery level full

Green ON when battery level in the right range

..

     Green blink when the system over voltage

     Green ON when solar is charging battery

LED INDICATOR

           10 minutes off before the controller start to work.

           The controller requires 10 minutes of continuous transition values before it starts to work. These constraints avoid false transitions due to lightning or dark storm clouds.  

           Press the power switch for 5 seconds, and select the desired LIGHTING CONTROL option. The LED is on, which confirmed you have selected the right one.

LIGHTING CONTROL OPTIONS  

 

7.      Press the BUTTON 0 or 9 to verify the system connecting.

6.      Connect the LIGHT last. If the red LED indicator lights, the battery capacity is low and should be charged before completing the system installation

5.      Connect the SOLAR(PV array) next. The green LED indicator will light if sunlight is present.

4.      Connect the BATTERY first. Use care that bare wires do not touch the metal case of the controller.

l         Use with 12V or 24V systems only

l         Use  with 12V or 24V batteries only

3.      It is recommended that the connections be made in order from 1 to 6. (see the following picture)

2.      Make sure the PV and load currents will not exceed the ratings of the controller being installed.

1.      Mount the controller to a vertical surface. Allow space above and below the controller for air flow.

This section provides a brief overview of how to get started using the controller. However, please review the entire manual to ensure best performance and years of trouble-free service.

QUICK START INSTRUCTIONS

Temperature:  -35 to +55

Temp Comp.(mV/)               -30mV                      -60mV

Float voltage                      13.6v                        27.2v

Boost voltage(10 minutes)         14.4v                        28.8v

Equalization voltage(10 minutes)   14.6v                        29.2v

Load reconnect                    12.6V                     25.20V

Load disconnect                   11.1V                     22.2V

25% Current overload              1 min.                     1 min.

Rated load                        5/10A                      5/10A

Rated solar input              5/10A                      5/10A

                      12Volt             24Volt

TECHNICAL INFORMATION

NOTES: For use with solar panels only

EPRC-MT-10   12V or 12/24V auto-work, 10Amp         

EPRC-MT-5,   12V or 12/24V auto-work, 5Amp          

RATINGS (12V or 12/24V auto work)

 

EPRC-ST-MT series

solar charge controller,

INSTRUCTION MANUAL

TECHNICAL INFORMATION
12Volt 24Volt
Rated solar input 5/10A

  • Maximum Current:5000
  • Rated Voltage:12/24V AUTO
  • Application:Solar System Controller
  • Model Number:20
  • Brand Name:OEM
  • Place of Origin:China (Mainland)
  • Country:China (Mainland)
  • telephone:86-574-62939602-803
Maximum Current: 5000
Rated Voltage: 12/24V AUTO
Application: Solar System Controller
Model Number: 20
Brand Name: OEM
Place of Origin: China (Mainland)
*Your name:
*Your Email:
*To:Ningbo kexin Co. Ltd
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters Remaining: 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

We do inquire for you , please wait ...