l Specifications are subject to change without prior notice.
l Typical BULK and FLOAT Setpoints for common Battery Types ( Note : For SBC-7108 / 7112 / 7120 only ) Please refer to battery manufacturer's specific recommended values
l (To protect against reverse polarity connection of PV panel and to block current from battery to PV panel when voltage of battery is higher than PV panel.)
.
14.5 VDC (FLOAT Voltage)
16.0 VDC (BULK Voltage),
:
NiCad or NiFe Alkaline battery (using 10 cells in series)
13.4 VDC (FLOAT Voltage)
14.6 VDC (BULK Voltage) ,
:
Deep-Cycle, Liquid Electrolyte Lead Antimony Battery
13.2 VDC (FLOAT Voltage)
14.3 VDC (BULK Voltage),
:
Maintenance-Free RV/Marine Lead Calcium Battery
13.5 VDC (FLOAT Voltage)
14.1 VDC (BULK Voltage) ,
:
Sealed Gel or A.G.M Lead Acid battery
.
Adjustable from 0.1 to 18 hours
:
Night-Lite mode ON duration time
Adjustable from 0-25.5V
:
Low Voltage Reconnect (LVR)
Adjustable from 0-25.5V
:
Low Voltage Disconnect (LVD)
DC load control mode ( For DC load terminal)
Adjustable from 12.0 - 16.0 V
:
Battery charging bulk voltage setting
Adjustable from 12.0 - 15.0 V
:
Battery charging float voltage setting
Yes
:
Over Temperature Protection
-10 to 50 ?XC
:
Operating Ambient Temperature
30 A
:
Fuse
150(W) x 85(D) x 45(H) mm
:
Dimension
0.47 kg
:
Weight
#12 AWG
:
Recommended wire size
3 - State LCD Display
:
Charging Status LCD indication
5 - State LED indications
:
Battery Status LED indication
Yes
:
Overcharge & Over-Discharge Protection
Yes
:
Battery Reverse Polarity Protection
Yes
:
Electronic Blocking
0.4 V
:
Voltage across terminals (Battery to Load)
0.8 V
:
Voltage across terminals (PV to Battery)
30 mA
:
Operation Current (no load and PV)
25 A
:
Maximum load current (5 mins.)
25 A
:
Maximum charge current (5 mins.)
20 A
:
Continuous charge / load current
26 VDC
:
Max. PV panel open circuit voltage
12 VDC
:
Battery Voltage
PV Charge Controller model: SBC - 7120
PV Charge Controller model: SBC - 7120 Battery Voltage : 12 VDC |
103g Weight 97 x 46 x 20.5 mm Dimension ( L x W x H ) 100% Relative Humidity -40 ~ +60?XC Ambient Temperature Range EN-55022 / EN-61001 / FCC Part 15 SUBPART B CLASS B Approvals 8A Max. Load Current (1 min.) 6A Rated Load Current 8A Max. Charging Current (5 min.) 6A Rated ...
Come From Renewable Energy Infrastructure Limited
103g Weight 97 x 46 x 20.5 mm Dimension ( L x W x H ) 100% Relative Humidity -40 ~ +60 C Ambient Temperature Range EN-55022 / EN-61001 / FCC Part 15 SUBPART B CLASS B Approvals Low Battery Shutdown for Load PV Voltage While Load Turn OFF PV Voltage While Load Turn ON Max. Load ...
Come From Renewable Energy Infrastructure Limited