working station

The user can set 03 electrical heating timings daily according his real need. Every set timing comes, only if the temperature is low than the set top limit and the circulation pump is out of working, the electrical starts and it will stop when temperature reaches top limit. The heating process can be stopped any time by pressing "STOP/SAVE".
6. Manually controlled auxiliary electrical heating
The user can press "HEAT / +" to start and press "STOP/SAVE" to stop the electrical heating when the temperature is lower than the set top limit and the pump is nt in operation
7. Lost power (power drop) protection
The system can save the settings, so all setting will not be lost when power is shut off.

5. Timing controlled auxiliary electrical heating

3. Manually control circulation pump;
When the differential temperature is less than set value, the pump can be operated manually. When the temperature is falling 95-99 degrees (including the two boundary temperature), the system will forbid the auto circulation of the pump to protect the vacuum tubes, because in that case the vacuum tubes may be emptily isolated. When the temperature reduce to normal, system auto circulation restores.
4. Temperature controlled auxiliary electrical heating;
When the temperature in the storage tank is lower than the set temperature and the circulation pump not in operation, the auxiliary electrical heating will start (if low limit set to 00, the auxiliary electrical heating will be shelled). When the temperature reaches to top limit, the heater will be stopped automatically. When the temperature is higher than the low limit and the time is not falling in the timing heating range, the user can press "STOP/SAVE" to end heating process.

2. Automatically control circulation pump;
When the temperature of the collector is higher to the storage tank temperature to a fixed figure (differential temperature which is set in advance). The circulation starts. When the two temperatures approach to each other, the pump stops.

1. Real time display of collector temperature and the storage tank temperature with system clock;
There are four digital highlighted displays. The display form is XX XX. Normally the controller displays only two temperatures. First two letter show collectors temperature, and the back two shows the storage tank temperature. When it is needed to check system time, press "SET" once, and the controller shows alternatively the two temperatures or hour and minute. For cancel time display, just press "SET" once again.

The main functions are as follows:

The controllers display two real time temperatures (one is inside the solar heat collecting panel, another is inside the storage tanks. It has one system clock and three programmable timers, which can be used to automatically control auxiliary electrical heater in the storage tank in case of need.

The automatic controllers are microprocessor based temperature differential controller. It is used for open and closed solar water systems etc. It controls the circulation pump operation according to the real time differential temperature gathered from the solar collecting panels and the storage tanks. If the differential temperature is reach the programmable temperature difference, the circulation pump starts, and when the differential temperature approaches to Zero, the pump stops.

Use method of the automatic controller:

Including: Circulating Pump, Safety valve, Check valve, Pressure guage, Flowmeter and Expansion Vessel.
Use this work station in the complete system (Split high pressure solar water heater) , just make it much more scientific and reasonable, it can solve this problem: avoid the water dirty that create by the water circulation in the circulatory pipe. Otherwise it is very convenient for installation, just need connect all parts.

working station

  • Country:China (Mainland)
  • telephone:86-519-83680935
working station
OEM is available,ISO,CCC,CE approval,professional,reliable,high efficiency
*Your name:
*Your Email:
*To:Jiangsu Sunhome New Energy Co., Ltd.
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters Remaining: 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

We do inquire for you , please wait ...

FJD RTK Base Station

$2,499.00 Tax excluded. Taxes and Shipping calculated at checkout Quantity: 1 Can be used with Autosteering Kit and 3D Excavator Guidance System Add to cart *Currently not available in Latin America, Mexico, Turkey, Japan, Brazil, and India. Pay with Ease Trusted Delivery ...

Come From FJ Dynamics Co., Ltd.

Gas Station

Gas Station, Hibachi Chicken, Smoke Shop, Starbucks Coffee, Convenience Store, Fried Chicken, Burgers and Sandwiches, Special Wines, Bitcoin, Hershey Icecream and Milkshake ...

Come From Exxon-Bryan's Grill

China made Axial seal ALD320-20X2 for power station

\"China made Axial seal ALD320-20X2 for power station YOYIK professional production and processing. Deyang YOYIK is located in Deyang city. The sale of products rich and authentic, to YOYIK buy peace of mind. Deyang YOYIK for power plants, steel accessories are as follows: ...

Come From DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD