The system can save the settings, so all setting not be lost when power is shut off.
The user can press HEAT / + to start and press STOP/SAVE to stop the electrical heating when the temperature is lower than the set top limit and the pump is not in operation
The user can set 03 electrical heating timing daily according his real need. Every set timing comes, only if the temperature is low than the set top limit and the circulation pump is out of working, the electrical starts and it will stop when temperature reaches top limit. The heating process can stopped any time by pressing STOP/SAVE.
When the temperature in the storage tank is lower than the set temperature and the circulation pump not in operation, the auxiliary electrical heating will start (if low limit set to 00, the auxiliary electrical heating will be shelled). When the temperature reaches to top limit, the heater will be stopped automatically. When the temperature is higher than the low limit and the time is not falling in the timing heating range, the user can press STOP/SAVE to end heating process.
When the differential temperature is less than set value, the pump can be operated manually. When the temperature is falling 95-99 degrees (including the two boundary temperature), the system will forbid the auto circulation of the pump to protect the vacuum tubes, because in that case the vacuum tubes may be emptily isolated. When the temperature reduce to normal, system auto circulation restores.
When the temperature of the collector is higher to the storage tank temperature to a fixed figure (differential temperature which is set in advance) The circulation starts. When the two temperatures approach to each other, the pump stops.
There are four digital highlighted displays. The display form is ** **. Normally the controller displays only two temperatures. First two letter show collectors temperature, and the back two shows the storage tank temperature. When it is needed to check system time, press SET once, and the controller shows alternatively the two temperatures or hour and minute. For cancel time display, just press SETonce again.
The main functions are as follows:
The automatic controller are microprocessor based temperature differential temperature gathered from the solar collecting panels and the storage tanks. If the differential temperature is reach the programmable temperature difference, the circulation pump starts, and when the differential temperature approaches to zero, the pump stops. The controllers display two real time temperatures (one is inside the solar heat collecting panel, another is inside the storage tanks. It has one system clock and three programmable timers, which can be used to automatically control auxiliary electrical heater in the storage tank in case of need.
Use method of the automatic controller:
remote control |
1. The size of this control box refers to the following dimensions; 2. The control box contains a DC circuit breaker; 3. The incoming and outgoing lines are wired with standard aviation plugs. Features of KE300D-03-01 Solar inverter control pump Excellent cooling performance ...
Come From Shenzhen MICNO Electric Co., Ltd.
All series of iPandee MPPT solar charging controllers incorporate new design concepts, keep up with the development of science and technology, adapt to the needs of cutting-edge off-grid system applications, and adopt our own patented MPPT control algorithm technology, which ...
A scc60amppt (maximum power point tracking) solar charge controller is a device used to optimize the charging of a battery or battery bank from a photovoltaic (PV) solar panel array. Some potential applications for the best 60 amp solar charge controller include: 1. Off-grid ...