6. Heating function: Electrical booster timing heating: Within 24 hours three pre-set time sections can be set, when the pre- set time comes, heating starts. When tank temperature is 5 C lower than the set temperature, electrical booster is triggered and heat water to the setting temperature.
5. Instantaneous circulation: Inorder to achieve the immediately hot water using, it is possible to start pipe circulation pump at any time. Working process: Pump operates for 3 minutes, and then stops automatically.
4.3. Operation principle withn the set time sections: During the set timesection, pumps works for three minutes, then stops for 15 minutes, ame process sontinues so.
4.2. The three time sections can be adjusted at will. Adjustable range: 00: 00-23: 50
This controller is possible to achieve timing hot water circulation within a day, three time sections can be set to trigger pump. The first timing section: Default 6: 00-8: 00. The second timing section: Default 10: 00-10: 00. Default is not working at this section. The third timing section: Default 19: 00-21: 00.
4.1. Timing circulation
4. Hot water circulation pump:
3.2. When the temperature difference between collector and water tank drops below the switch-off temperature difference, then solar circuir prmp stops. Adjustable switch-off temperature difference is 1-10K, default value is 5K.
3.1. When the temperature difference between the collector (T2)and the tank (T3) is exceeded the swich-on temperature difference, solar circuit pump is triggered to transfer heat from collector to tank; The adjustable range of switch-on temperature difference is 2-15K, default value is 10K.
3. Temperature difference controlled solar circulation pump:
2. indicating of water temperature: Display actual water temperature at solar collector and at water tank.
1. Clock: Display 24 hours clock time.
Main Functions:
5. Available power of controlled pump: <600W
4. Range of temperature measuring: 0-99ºC
3. Accuracy of temperature measuring: 2ºC
2. Power supplier: AC220V
1. Display dimension: 495mm x 170mm x 65mm
Technical Data:
It is developed with the newest Sumsun high performance SCM and specially designed for solar unpressurized system. It possesses nice appearance, reliability and stable performance, and it is easy to install. It is the most ideal device of solar system.
Solar Controlling System SR618C1 (CE ISO SGS Approved)
CE ISO Approved Solar Water Heater Controller for Solar Energy Thermal System Manufacturer 11 years.
1.Sample available
2.10% discount on container loadage
3.20% off on DHL, 30% off on TNT
11 years old Manufacturer.
1.Sample available
2.10% discount on 20ft full fcontainer loadage
3.20% off on DHL, 30% off on TNT
Delivery Time: | 5 days via DHL, 10 days via shipping |
Package: | Standard Export Carton |
Supply Ability: | 150 Set/Sets per Day |
Minimum Order Quantity: | 30 Set/Sets |
Payment Terms: | T/T,Western Union,Credit cards |
Port: | Shanghai |
Fob Price: | US$90-150Shanghai |
Rated Voltage: | 110V 220V 230V |
Application: | Water Heater Controller |
Model Number: | SR618C1 |
Brand Name: | SKYLIGHT / OEM |
Place of Origin: | Jiangsu China (Mainland) |
The household solar power supply systems are mainly aimed at home users. With the maturity of solar energy technology and the decline in costs, solar power generation, which was originally only used in commercial and industrial fields, has been slowly extended to the civilian ...
Commercial solar power supply systems are mainly aimed at high-power commercial and industrial electricity applications. If your house has many high-power appliances and the daily power consumption is large, then the 15KW 20KW 30KW 50KW off grid solar power systems are prepared ...
Three phase solar power generation systems can also be applied to commercial, industrial, and government power stations. Compared with the grid-tied system for home use, the grid-tied system for industrial and commercial use in order to meet the daily power consumption, the ...
1. The size of this control box refers to the following dimensions; 2. The control box contains a DC circuit breaker; 3. The incoming and outgoing lines are wired with standard aviation plugs. Features of KE300D-03-01 Solar inverter control pump Excellent cooling performance ...
Come From Shenzhen MICNO Electric Co., Ltd.
Off-grid Solar Power System 15-50kw Anern 15kw-50kw off-grid solar system is a highly reliable off grid hybrid solar system. This series of off-grid solar systems use high-frequency off grid solar inverters to ensure the safe and stable operation of high-power motors. With ...
All series of iPandee MPPT solar charging controllers incorporate new design concepts, keep up with the development of science and technology, adapt to the needs of cutting-edge off-grid system applications, and adopt our own patented MPPT control algorithm technology, which ...
A scc60amppt (maximum power point tracking) solar charge controller is a device used to optimize the charging of a battery or battery bank from a photovoltaic (PV) solar panel array. Some potential applications for the best 60 amp solar charge controller include: 1. Off-grid ...
A 50a solar controller is a useful addition to any solar power system that has a high power demand or that requires a large battery bank. It can help to improve the charging performance and overall system performance, making it an excellent choice for those who rely on solar ...
A solar battery charger 48v controller is a device that is used to regulate the charge of a 48V solar panel battery system. It functions in a similar way to a 36V MPPT charge controller, by maximizing the power output of the solar panels and efficiently charging the battery. ...
A 36 volt solar panel charge controller is a device that is used to regulate the charge of a 36V solar panel battery system. It does this by maximizing the power output of the solar panels and efficiently charging the battery. The MPPT (maximum power point tracking) feature of ...