pH/ORP CONTROLLERS #015246 HyDAC Digital pH Controller, painted steel enclosure, 20 amp relay, digital pH display (0-14 pH), time-out, no flow module, pre-wired and pre-plumbed piping assembly PVC
Sch. 80 includes flow switch, pH probe, sample petcock and pH buffer kit, 115 VAC, 60 Hz.
#016168 HyDAC Digital ORP Controller, painted steel enclosure, 20 amp relay, digital mv display (-1999 to +1999), time-out no-flow module, pre-wired and pre-plumbed piping assembly PVC Sch. 80
includes flow switch, ORP probe, sample petcock, 115 VAC, 60 Hz.
#016089 HyDAC Combination ORP and pH Controller, painted steel enclosure, 20 amp relay, digital pH display (0-14 pH) and digital ORP display (-1999 to +1999 mv), time-out on both pumps, alarm
flasher and no-flow module, pre-wired and pre-plumbed piping assembly PVC Sch. 80 includes, flow switch, pH & ORP probe, sample petcock, 115 VAC, 60 Hz.
pH/ORP PROBES AND ASSEMBLIES .
PIPING ASSEMBLY (Includes probe, flow switch and sample petcock) #015286 pH, flow-thru, PVC N/A 3/4" NPT 100 psi 115 F
#015285 pH, flow-thru, CPVC N/A 3/4" NPT 100 psi 150 F
#016088 ORP/pH, flow-thru, PVC N/A 3/4" NPT 100 psi 150 F
#035250 ORP flow-thru, PVC N/A 3/4" NPT 100 psi 150 F
pH (Probe assembly only) #015156 Flow-thru, CPVC with tee N/A 3/4" NPT 100 psi 150 F
#015508 Flow thru, CPVC with tee N/A 3/4" NPT 150 psi 150 F
#034889 Submersible pH Probe with 20 ft. cable and BNC connector.
#028322 pH Probe with BNC connector (probe only).
#012094 Submersible pH probe "self-cleaning" (S650CD); required 012095 cable assembly -- probe only.
#012095 Cable Assembly with 20 ft. cable & BNC connector for above (012094) pH probe (S653).
#016128 ORP Probe mounted in 3/4" PVC Sch. 80 tee.
#032639 Combination Redox/Reference ORP Probe with 30" cable and BNC connector (probe only).
#032640 Combination Redox/Reference Submersible ORP probe with 20 ft. cable and BNC connector (probe only).
#015246 HyDAC Digital pH Controller, painted steel enclosure, 20 amp relay, digital pH display (0-14 pH), |
EDI PLANT WATER TREATMENT EDI plant water treatment module is usually placed behind the reverse osmosis system, which not only overcomes the lack of deep desalination of reverse osmosis effluent, but also further removes trace carbon dioxide, residual salt, silicon dioxide, ...