Automatic shut-off valve: Class D (Class C on request)
Working temperature range: 0...70o C (-20...60o C on request)
Maximum outlet pressure setting range: 3...30 mbar (20...50 on request)
Maximum gad inlet pressure: 60 mbar
gas families: I, II, IIIG
Installation positions: any position
Gas connections: Rp 1/2/ ISO 7
Technical Data
Connection for combustion chamber pressure regulator compensation.
Threaded gas inlet and outlet with provision for flange connection.
Inlet and outlet pressure test points.
Inlet and pilot filters.
Pilot outlet with gas flow adjustment screw.
Main gas flow control(optional).
Step opening ignition device (optional).
Servo-controlled pressure regulator.
Near silent shut-off valve.
Thermoelectric flame supervision device with re-start interlock.
Control knob with off, pilot and on positions.
Control knob with off, pilot and on positions. Thermoelectric flame supervision device with re-start interlock. Near silent sh |