28 MW Steam Turbine Power Plant
Two (2) 14 MW Stal Laval Steam Turbines, one that operates at high pressure and other that operates at low pressure. Turbine 1: Norm: 107 barg, Max 127 barg, Steam Temperature before valve Norm 530 C, Max Temperature 540 C, Extraction pressure 45 barg, Back Pressure 25 barg. Turbine 2: Norm: 25 barg, Max 40 barg, Steam Temperature before valve Norm 350 C, Max Temperature 425 C, Extraction pressure 6,2 barg, Back Pressure 1,8 barg Complete plant in good condition, well maintained and has provided reliable operation since installation., 50 HZ, 5250V, Complete plant
Post by Rose Pelrine Electrical Equipment & Supplies @2013-11-26 20:59:06