Model/parameter | TC4208 | TC4708 | TC4808 | TC4810 | TC5008 | |||
Rated lifting moment | KN.m | 400 | 400 | 400 | 400 | 500 | ||
Max. load | t | 4.0 | 4.0 | 4.0 | 4.0 | 4.0 | ||
Radius | m | 42 | 47 | 48 | 48 | 50 | ||
Lifting height | Independent | m | 30 | 30 | 29 | 30 | 29 | |
Attached | 100 | 120 | 120 | 120 | 120 | |||
Lifting speed | 2 falls | m/min | 66/33/11.6 | 66/33/11.6 | 70/35/7.7 | 66/33/11.6 | 70/35/7.7 | |
4 falls | 33/16.5/5.8 | 33/16.5/5.8 | 35/17.5/3.75 | 33/16.5/5.8 | 35/17.5/3.75 | |||
Tip load | t | 0.8 | 0.8 | 0.8 | 1.0 | 0.8 | ||
Trolleying speed | m/min | 22/44 | 22/44 | 22/33 | 22/44 | 22/33 | ||
Slewing speed | r/min | 0.56/0.72 | 0-0.6 | 0-0.6 | 0-0.6 | 0-0.6 | ||
Jacking speed | m/min | 0.54 | 0.6 | 0.4 | 0.6 | 0.4 | ||
Structure selfweight | t | 19/31 | 21/32 |
|
24/35 |
|
||
Balanced weight | t | 25.7 | 25.7 |
|
25.7 |
|
||
Working temperature | degree | -20-+40 | ||||||
Working voltage | v | 380v±5% | ||||||
Working air pressure | N/m2 |
250 |