Global Free Trade Posts |
1) Fire Pump:2 sets Type: Horizontal, single stage, centrifugal pump Duty Specified Capacity: 600 m3/h Total Head: 130 m L.C. Speed: 2100 rpm Power absorbed : 273.6 kW (Seawater) Efficiency: 80% Discharge : Top, DN200 PN 25 ...
Post by Emma Chen [Security & Protection] @2012-12-31 14:17:36
Driven by:Diesel engine. The fire pump and engine will be installed on a common base. Consisting of: 1) Fire Pump:2 sets Type: Horizontal, single stage, centrifugal pump Duty Specified Capacity: 600 m3/h Total Head: 130 m L.C. ...
Post by Emma Chen [Security & Protection] @2012-12-31 14:17:02
high pressure water-base fire extinguishing system China Deyuan Marine Fitting Co.,ltd are leading supplier of carbon dioxide fire extinguishing system,local water-based fire fighting system,fixed foam fire fighting plant,water spray...
Post by Robin Shen [Security & Protection] @2012-12-31 14:11:53
low pressure water-base fire-fighting system China Deyuan Marine Fitting Co.,ltd are leading supplier of carbon dioxide fire extinguishing system,local water-based fire fighting system,fixed foam fire fighting plant,water spray fire...
Post by Robin Shen [Security & Protection] @2012-12-31 14:11:31
China Deyuan Marine Fitting Co.,ltd are leading supplier of carbon dioxide fire extinguishing system,local water-based fire fighting system,fixed foam fire fighting plant,water spray fire extinguishing system.Pls contact us for more...
Post by Robin Shen [Security & Protection] @2012-12-31 14:11:09
CO2 fire extinguishing system China Deyuan Marine Fitting Co.,ltd are leading supplier of carbon dioxide fire extinguishing system,local water-based fire fighting system,fixed foam fire fighting plant,water spray fire extinguishing...
Post by Robin Shen [Security & Protection] @2012-12-31 14:09:44
China Deyuan Marine Fitting Co.,ltd are leading supplier of marine fire extinguisher,we can offer dry powder fire extinguisher,,foam fire extinguisher,hanging dry powder fire extinguisher,CO2 fire extinguisher,wheeled dry powder fire...
Post by Robin Shen [Security & Protection] @2012-12-31 14:08:24
China Deyuan Marine Fitting Co.,ltd are leading supplier of marine SYS CO2 Fire-extinguishing system.carbon dioxide fire extinguishing system. low pressure water-base fire-fighting system.high pressure water-base fire extinguishing...
Post by Robin Shen [Security & Protection] @2012-12-31 14:07:59
SS300EL Double Pipe Monitor Standard Design Parameters SS300DEL/F Descriptions: Produced on requirement Effective capacity: 60000L/min The max pressure: 16bar Inlet: Flange DN300 PN16 Outlet: Flange connection Optional inlet...
Post by Robin Shen [Security & Protection] @2012-12-31 14:07:37
SS300EL Standard Design Parameters SS300EL/F Descriptions: Produced on requirement Effective capacity: 60000L/min The max pressure: 16bar Inlet: Flange DN300 PN16 Outlet: Flange connection Optional inlet flange: ANSI12''...
Post by Robin Shen [Security & Protection] @2012-12-31 14:07:14
SS250EL Standard Design Parameters SS250EL/F Descriptions: Produced on requirement Effective capacity: 32000L/min The max pressure: 16bar Inlet: Flange DN250 PN16 Outlet: Flange connection Optional inlet : Flange DN300 /...
Post by Robin Shen [Security & Protection] @2012-12-31 14:06:52
SS200EL Standard Design Parameters SS200EL/F; SS200WEL/F Descriptions: Produced on requirement Effective capacity: 26000L/min The max pressure: 16bar Inlet: Flange DN200 PN16 Outlet: Square flange Optional inlet : DN250 /...
Post by Robin Shen [Security & Protection] @2012-12-31 14:06:30
SS150 Standard Design Parameters SS150EL/F; SS150DEL/F Descriptions: Produced on requirement Effective capacity: 18000L/min The max pressure: 16bar Inlet: Flange DN150 PN16 Outlet: Flange connection Optional inlet : DN200 /...
Post by Robin Shen [Security & Protection] @2012-12-31 14:06:06
SS100EL Standard Design Parameters SS100EL/F Descriptions: Produced on requirement Effective capacity: 6000L/min The max pressure: 16bar Inlet: Flange DN100 PN16 Outlet: Screw thread Optional inlet flange: DN150 / ANSI4''...
Post by Robin Shen [Security & Protection] @2012-12-31 14:05:40
SS80EL Standard Design Parameters SS80WEL/F; SS80EL/F Descriptions: Produced on requirement Effective capacity: 4000L/min The max pressure: 16bar Inlet: Flange DN80 PN16 Outlet: Screw thread Optional inlet flange: DN100 PN16/...
Post by Robin Shen [Security & Protection] @2012-12-31 14:05:19
Fire Monitor with Adjustment by Electric Motor SS65EL Standard Design Parameters SS65FEL/F Descriptions:Produced on requirement Effective capacity: 2400L/min The max pressure: 16bar Inlet: Flange DN65 PN16 Outlet: 2'' screw...
Post by Robin Shen [Security & Protection] @2012-12-31 14:04:23
SS250 Standard Design Parameters SS250HR/F Descriptions: Produced on requirement Effective capacity: 32000L/min The max pressure: 16bar Inlet: Flange DN250 PN16 Outlet: Flange connection Optional inlet flange: DN300/ ANSI10''...
Post by Robin Shen [Security & Protection] @2012-12-31 14:03:59
SS200 Standard Design Parameters SS200HR/F Descriptions: Produced on requirement Effective capacity: 26000L/min The max pressure: 16bar Inlet: Flange DN200 PN16 Outlet: Flange connection Optional inlet flange: DN250 / ANSI8''...
Post by Robin Shen [Security & Protection] @2012-12-31 14:03:39
SS150 Double Pipe Monitor Standard Design Parameters (SS150DHR/F) Descriptions: Produced on requirement Effective capacity: 1800L/min The max pressure: 16bar Inlet: Flange DN150 PN16 Outlet: Flange connection Optional inlet...
Post by Robin Shen [Security & Protection] @2012-12-31 14:03:20
SS150 Standard Design Parameters (SS150WHL/F;SS150FHR/F) Descriptions: Produced on requirement Effective capacity: 1800L/min The max pressure: 16bar Inlet: Flange DN150 PN16 Outlet: Flange connection Optional inlet : DN200...
Post by Robin Shen [Security & Protection] @2012-12-31 14:02:58