Bacterial Filtration Efficiency Tester Of Medical protective clothing test

Product Quick Detail

Place Of Origin
china
Minimum Order
1
Packaging
Packed by solid wooden case;
Delivery
7 Days

Face Masks bacterial filtration efficiency BFE tester is to determine the bacterial filtration efficiency (BFE) of medical face mask materials by employing a ratio of the upstream bacterial challenge to downstream residual concentration of the tested medical face mask materials. The tester provides certain flow rate of bacterial aerosol. The operator can measure the number of colony forming units passing through the medical face mask material, which is clamped between a six-stage Anderson cascade impactor and an aerosol chamber, expressed as a percentage of the number of colony forming units present in the challenge aerosol.

Standards

EN 14683 Medical face masks-Requirements and test methods.
ASTM F2101 Standard Test Method for Evaluating the Bacterial Filtration Efficiency (BFE) of Medical Face Mask Materials, Using a Biological Aerosol of Staphylococcus aureus.
ASTM F2100 Standard Specification for Performance of Materials Used in Medical Face Masks
YY 0469 Technical requirements for surgical mask.

Features

Double six-stage Anderson microbial sampler test systems with contrast sampling tests provide high accuracy.

Internal aerosol generator provides stable and adjustable microbial aerosol flow. Internal pump can adjust the flow rate.

Equipped negative pressure test chamber to ensure the safety of operators. Equipped light system to make the operations more clear and easy to do.

10.4 Inch touch screen control panel is easy to operate and supports USB data transmission.

Equipped leakage protection and operating window provide better operating view and safety operating conditions.

Stainless steel chamber with insulation and fire retardant lining is stable and reliable.



The main parameters of the mask bacterial filtration efficiency tester:
1.Sampling flow rate of channel A: parameter range, 28.3L / min; resolution, 0.1L / min; maximum allowable error: better than ±2.5%;
Channel B sampling flow rate: parameter range, 28.3L / min; resolution, 0.1L / min; maximum allowable error: better than ± 2.5%;
2.Spray flow: parameter range, (8 ~ 10) L / min; resolution, 0.1L / min; maximum allowable error: better than ± 5.0%;
3.Flow rate of peristaltic pump: parameter range, (0.006 ~ 3.0) mL / min; resolution, 0.001ml / min; maximum allowable error: better than ± 2.5%;
4.Front pressure of A-channel flowmeter: parameter range, (-20 ~ 0) kPa; resolution, 0.01kPa; maximum allowable error: better than ± 2.5%;
Front pressure of B-channel flowmeter: parameter range, (-20 ~ 0) kPa; resolution, 0.01kPa; maximum allowable error: better than ±2.5%;
5.Front pressure of spray flow meter: parameter range, (0 ~ 300) kPa; resolution, 0.1kPa; maximum allowable error: better than ± 2.5%;
6.Negative pressure of aerosol chamber: parameter range, (-90 ~ -120) Pa; resolution, 0.1Pa; maximum allowable error: better than ± 2.0%;
7.Data storage capacity:> 100000 groups;
8.High-efficiency air filter characteristics: the filtration efficiency of particles above 0.3um is ≥99.99%;
9.Mass median diameter of aerosol generator: average particle diameter (3.0 ± 0.3) μm, geometric standard deviation ≤1.5.






  • Country:
  • Business Type:
  • Market:
  • Founded Year:
  • Address:
  • Contact:QIAN qian
*Your name:
*Your Email:
*To:Qinsun Instruments (Shanghai) Co., Ltd.
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters : 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

submiting now We do inquire for you , please wait ...