361MC Atomic Absorption Spectrometer

Packaging
N/A
Delivery
15 Days

I. Key Features

1.Feature-rich: The computer automatically deducted blank value sensitivity drift deducted, automatically deduct baseline drift, and automatically calculate the average and deviation, curve equation work automatically calculate and reading the concentration, automatic printing reports, but also for flame emission photometry method, hydride generation atomic absorption and atomic absorption analysis. The sensitivity of the last two kinds of graphite furnace level, but the price is far lower than the graphite furnace.

2. simple: after setting the condition press the keys two time at each test only, both read / print out the absorbance, the concentration and the relative standard deviation. Compared with non-computer equipment saving a lot of manual data processing time.

3. Signal stability: the use of imported high-quality photomultiplier tubes and advanced integrated circuits, single-beam light path,strong light monochromator and efficient atomizer, low noise, high accuracy. Computer logarithmic transformation accurately, drift-free, baseline stability.

4. Expert System: beginner's teacher and consultant (only 361CRT type).

5. Anti-corrosive atomization system: high quality plastic spray chamber, the combustion head with long life, fast thermal equilibrium titanium head, it without water cooling and can achieve for a long time measurement, sensitivity does not change.

6. Efficient atomizer: high sensitivity and high reproducibility guarantee.

7. Peak searching accurately: fine-tuning the wavelength of a special agency to accurately align the wavelength of the peak position.

8. Continuous slit: original continuous slit agencies to ensure a high spectral resolution and get the best bandwidth .

9. Antirust performance: pure quality engineering plastic spray chamber solve the problem of corrosion and hydrophilic completely .

10. Security: The second explosion-proof measure, even though air interrupt, nor will an accident happens.

11. Fully furnished: Can be used immediately after purchase. Supporting a variety of optional combination, greatly expanding the range of applications of the machine.

II.Technical indicators:

1. Wavelength range: 190nm ~ 900nm

2. Wavelength Indication error: ≤ ± 0.5nm

3. Wavelength Repeatability: better than 0.3nm (single direction)

4. Resolution: manganese lane wave valley <40% (when the Spectral bandwidth at 0.2nm)

5. Baseline Stability: Better than 0.004A/30min (copper)

6. Detection limit of: <0.007μg/ml (copper)

7. Characteristic concentration: <0.04μg/ml/1% (copper)

8. Sower supply: AC220V ± 22V/50Hz AC110V ± 11V/60Hz

  • Country: China (Mainland)
  • Business Type:
  • Market:
  • Founded Year:2013
  • Address:
  • Contact:Angel Chan
*Your name:
*Your Email:
*To:Zhuhai Dshing Import&Export Co.,ltd
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters : 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

submiting now We do inquire for you , please wait ...

DSHX-6 Flame Zeeman Atomic Absorption Spectrometer
DSHX-6 Flame Zeeman Atomic Absorption Spectrometer

I.Features 1.This is a kind of Zeeman background correction AAS which used Zeeman detection system designed by ourselves (patent No.: 27523). 2.It has higher detection efficiency, better signal and noisy ratio, therefore, the instrument with Zeeman system is better than same ...

Zhuhai Dshing Import&Export Co.,ltd

DSHX-600 Atomic Absorption Spectrometer
DSHX-600 Atomic Absorption Spectrometer

I.Technical Features 1.Deuterium lamp background correction system. 2.Selection in double lamp and lamps auto conversion device. 3.Auto-wavelength scanning setting, auto-lamp current, auto-voltage and auto-regulation of energy. 4.Flame monitoring protection system. 5.Titanium ...

Zhuhai Dshing Import&Export Co.,ltd

DSHX-610 Flame Atomic Absorption Spectrometer
DSHX-610 Flame Atomic Absorption Spectrometer

I.Features 1.Deuterium lamp background correction system. 2.Grating 1800L/mm, short focal length 270mm, better signal and noisy ratio. 3.Auto-wavelength scanning,auto-lamp current,negative auto-voltage and auto- energy balance of cathode lamp and deuterium lamp. 4.High ...

Zhuhai Dshing Import&Export Co.,ltd