Main Function:
High resolution engineering geological exploration such as factory foundations, highways, bridges, railways, civil engineering, hydrology, engineering, environmental etc.
High-resolution research, tomography and monitoring applications.
Coal mining gobs, caves of Custer area, geological disasters survey like landslides other geological disasters.
Landslides and other geological disaster exploration.
Metal and non-metallic mineral resources exploration and geothermal exploration.
System Composition
One DSHZ-6A multi-functional DC resistivity instrument as the survey and control unit in the system, equipped with a DSHK-2A type 60-channel or 120-channel multiplex electrode switch manufactured by our factory, and cables, electrodes and other related accessories, together to form the resistivity imaging system.
Main Advantages
Easy for Operation: adopting all-digital automatic measurement,execute automatic compensation for spontaneous potential, drift and electrode polarization.
By adopting large screen LCD display in Chinese characters, more than fourteen types of wiring working mode can be directly displayed in high-density measurement mode;
In DSHD-6A stand-alone mode, nine types of electrode arranging methods can be directly displayed; meanwhile, real-time curve display can be realized during working.
Multiple function in one machine: having four functions including long lead IP instrument, 2D high density resistivity meter, 2D high-density IP instrument, and medium-power short lead transmitter.
Extra-large Storage: In high-density mode, store the measured data at 120,000 measuring points; in DSHD-6A stand-alone mode, the instrument can store the measured data at 4,800 measuring points;
There are 22 digits at each measuring points, provided with RS-232 serial interface, and the stored data can be transferred to the computer by appropriate software to launch digital interpretation for various methods.
Specifications:
Measuring unit ( DSHD-6A)
Measuring Current Accuracy: (at Ip>10mA)±5%, ±1 digit; (at Ip<10mA) ±1% ±Letter
Measuring Voltage Accuracy: (at Vp>10mV)±5%, ±1 digit; (at Vp<10mV)±1%, ±1 digit
Maximum Measuring Voltage: -6000mV~+6000mV
Measuring Voltage Resolution: 0.01 mV
Suppression on 50Hz Power Frequency: 80dB
Measuring Current: 0~5000 mA
Measuring Current Resolution: 0.01 mA
Input Impedance :≥50 MΩ
Measured Apparent Polarizability Accuracy: ±1%, ±1 digit
Maximum Power Supply Voltage :900V
Maximum Power Supply Current: 5A
Power Supply Pulse Width: 1~60 sec.
Weight: 8 kg
Volume: 305×200×202mm
DSHK-2A Multiplex Electrode Converter
Operating Mode: 16-key keypad with 90 character LCD display combines to form man-machine dialogue operation.
Sopported manual configuration: Wenner, Schlumberger 1, Schlumberger 2, Dipole-Dipole, Combined Profiles, Differential, Pole-Pole, Triple-Pole Rolling,
Conversion Electrodes: 60 channels or 120 channels
Maximum Allowable Current: 2A
Maximum Withstand Voltage: 500V DC
Insulating Property: 500MΩ
Electroshock Break-over Resistance: smaller than 0.1Ω
Power Consumption: 50 mA (Standby)
Power Supply: 1# Dry Cell (or rechargeable battery with the same specification) 8 pcs.
Working Temperature: -10℃~ +50℃, 95%Rh
Weight: 7 kg (60 channels), 7.5kg (120 channels)
Volume: 305×200×202mm (60 channels), 324×200×245mm (120 channels)
Main Applications · Widely used for high-resolution research, tomography and monitoring applications. · Coal mining gobs, caves of Custer area, geological disasters survey like landslides other geological disasters. · High resolution engineering geological exploration like ...