Brief Introdcution:
Purpose
(1) It can be used to determine mass% of total sulfur in the crude petroleum, petroleum, heavy oil, diesel oil, gasoline, and naphtha.
(2) It can be used to determine total sulfur content in the products of coal chemical industry, such as primary benzene.
(3) It can be used to determine total sulfur or sulfide in other liquid or solid powder samples.
Technical specifications and parameters
1. Instrument characteristics
(1) With electrical, mechanical and microprocessor integration design, so it is compact and beautiful;
(2) It can determine various products and in a wide measurement range. It is rapid for analysis and it only need little standard sample.
(3) Adopts fluorescence intensity ratio analysis methods, it can make correction to temperature and pressure automatically and it can also make correction to ratio of carbon and
hydrogen (C/H).
(4) Large LCD for display; Man-machine conversation system; Sound alarm for operation mistake;
(5) It has self-diagnostic function, so it can determine its working state and electric parameters by making counting measurement and energy spectrum measurement using reference
samples.
(6) Equipped with a RS232 serial port, it can connect with any computer or web system.
(7) It takes disposable sample cell with Mylar film, so it can avoid cross contamination. Sample cell is made by a multifunctional pressure shaping device, so it is rapid and
convenient. There is a hole on the sample cell cover and you can record sample serial number, S% (m/m), and date on the sample cell cover.
(8) The sample holder is installed on a slide rail, so it can move out and move in automatically. It can move out from inside of the instrument for sample location and anti-leakage
parts replacement. It is convenient and it can avoid any contamination to detection system.
(9) It can save large quantity of test data. You can browse test data and calibration curves at any time.
(10) It uses a thermal printer, so it is easy to replace printing paper.
(11) Tightly protection measures to avoid oil leakage. The sample cell is placed on the leakage protection device. The sample cell can enter into the detection system together with
the leakage protection device only during sample analysis procedures. If the instrument is not at sample analysis state, the leakage protection device will move out, so this can avoid any
contamination to the detection system.
(12) Its safe X-ray protection measures can keep people from injury of X-ray radiation.
4. Main technical specification and parameters
(1) Measurement range: 7 ppm to 5%
(2) Repeatability (r):
(3) Reproducibility (R): <0.1215(X+0.5555)
(4) Detection limit: 7 ppm
(5) Oil sample quantity: 2.5 ml (it is equal to sample depth of 4.5 mm)
(6) Measurement time: it can preset 60, 120, 240, 300, and 600 s at random
(7) It can make measurement automatically for single sample. Repeat times: can set 2, 3, 5, 10, and 50 at random; it will show average value and standard deviation at end of measurement.
(8) Calibration curve numbers: it can save 9 calibration curves. 5 pieces of them are unary linear equation and 4 pieces of them are unary quadratic equation.
(9) Working condition:
a. Ambient temperature: 5~40°C
b. Relative humidity: ≤85% (30 °C)
(10) Power supply: AC 220V±20V, 50 Hz; Rated power: 30 W
(11) Size and weight: 468mm×368mm×136mm; 13 kg
SDS-IVa can be used to determine the total sulfur content in combustibles such as coal, coke, petroleum and other solid biomass fuels in the field of power plant, coal mining, cement & steel factory etc.Test reliable, ...
SDS720 can be used to determine the total sulfur content in combustibles such as coal, coke, petroleum and other solid biomass fuels in the field of power plant, coal mining, cement & steel factory etc.21 samples loaded once, high test efficiency.With digital flow meter, ...
A: Summary and purpose 1. Summary DSHD-17040 X-ray Fluorescence Sulfur Analyzeris specially designed to determine sulfur content in the petroleum products. Adopts energy-dispersive principle, and with electrical, mechanical and microprocessor integration design, so ...
I Brief Introduction GD-17040 ASTMD 4294 X-ray Fluorescence Petroleum Oil Sulfur Content Analyzer is specially designed to determine sulfur content in the petroleum products. Adopts energy-dispersive principle, and with integrated design, it is rapid and accurate. It can meet ...
Summary The instrument is specially designed to determine sulfur content in the petroleum products. Adopts energy-dispersive principle, and with electrical, mechanical and microprocessor integration design, so it is rapid and accurate. It can meet the requirements of national ...
A: Summary and purpose 1. Summary DSHD-17040 X-ray Fluorescence Sulfur Analyzer is specially designed to determine sulfur content in the petroleum products. Adopts energy-dispersive principle, and with electrical, mechanical and microprocessor integration design, so it ...
1. Based on the mature technology of desktop X-ray fluorescence analyzer and the latest technological development, and on the performance of the existing international commercial handheld X-ray fluorescence analyzer, adding new elements into it on the basis of the first, ...
I. Application fields 1. Content determination of precious metals Au, Pt, Ag, etc and jewelries 2. Thickness measurement of metal plating and content determination of plating solutions and plating 3. Precious metals and jewelries processing industries, banks, jewelries shops ...
I.Introduction DSHG-7X Handheld Xrf Soil Analyzer can do site analysis for various conditions. The function includes site analysis for in situ soil to investigate local environment and apply in soil and water conservation project.The operator can analyze local soil directly or ...
I.Introduction The DSHG uses X-Ray Fluorescence (XRF) for a quick and completely non-destructive method of testing for lead free manufacturing, RoHS compliance and the detection of heavy metals in toys and consumer products. The DSHG provides rapid and accurate analysis on ...