GD-2122B Automatic Karl Fischer Titrator

Place Of Origin
Chongqing of China
Packaging
Wooden Case
Delivery
10 Days

Summary
The instrument is designed and made as per national standard of China GB/T 7600 Standard Test Method for Water Content of Transformer Oil in Service (Coulometric Method), industrial standard of China SH/T0246 Standard Test Method for Water Content of Light Oils (Coulometry). ASTM D1533 Standard Test Method for Water in Insulating Liquids by Coulometric Karl Fischer Titration and ASTM D6304 Standard Test Method for Determination of Water in Petroleum Products,Lubricating Oils and Additives by Karl Fischer Titration. It is used to determine water content in the liquid petroleum products.

I. Main Technical Features
Adopting microcomputer technology, the instrument has characteristics of rapid analysis,high precision, LCD indication and automatic printing. It also has functions of self-diagnosis and menu selection. It is a kind of multifunction and automatic analyzer.

II. Main Technical Specifications
1. Titration mode: Coulometric Karl Fischer titration
2. Measurement range: 1 μg~100 mg (typical value is 10 μg~10 mg)
3. Maximum current: 400 mA, automatic control
4. Maximum titration speed: 2 mg per minute (maximum)
5. Precision: (1)10 μg~1 mg: ±3 μg (2) Above 1mg: ±0.3%
6. End point indication:Visual display, acoustic beep. The indication light will be on. Print out.
7. Date display format: Year/Month/Day, Hour/Minute/Second
8. Printer: 16 character thermal printer, width 44 mm.
9. Power supply: AC 220V±10%, 50 Hz±5%
10. Power consumption: 60 W
11. Ambient temperature: 5℃~40 ℃
12. Relative humidity: ≤85%
13. Dimension: 400mm×300mm×240mm
14. Weight: 9 kg

Related Products
GD-260 Water Content Tester
GD-260A Water Content Tester (Double Units)
GD-2122 Water Content Tester(Karl Fischer Method)
GD-8929 Crude Petroleum Water Content Tester

  • Country: China (Mainland)
  • Business Type:
  • Market:
  • Founded Year:2009
  • Address:重庆市南岸区南坪金台大厦9-10
  • Contact:Daisy Tao
*Your name:
*Your Email:
*To:重庆格纳迪机电设备有限公司
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters : 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

submiting now We do inquire for you , please wait ...

KR-605 Fully Automatic Karl Fischer Moisture Titrator
KR-605 Fully Automatic Karl Fischer Moisture Titrator

pplication: This KR-605 water content tester adopts the global recognized classical moisture testing method - Karl Fischer Coulometric Method which is the most accuratemethod with low cost. With the universal standard and analyzing method, it can quickly analyze the moisture ...

Chongqing Kolery Trading Co., Ltd

DSHD-2122 Karl Fischer Titrator
DSHD-2122 Karl Fischer Titrator

A:Brief description: DSHD-2122 Karl Fischer Titrator is designed accordingthe National Standard of People\'s Republic of China GB/T 11133 Liquid petroleum products-Determination of water-Karl Fischer reagent method and the Enterprise Standard of Shanghai City Q/YXYY 14. ...

Dshing Instrument Co.,Ltd

DSHD-2122B Automatic Karl Fischer Titrator
DSHD-2122B Automatic Karl Fischer Titrator

A:Brief description:     DSHD-2122B Automatic Karl Fischer Titrator is designedaccordingthe National Standard of People\'s Republic of China GB7600 Test Method for Water Content of Transformer Oil in Service (Coulometric Method), and the Industry Standard of People\'s ...

Dshing Instrument Co.,Ltd

GDD-1A Automatic Volumetric Karl Fischer Mositure Titrator
GDD-1A Automatic Volumetric Karl Fischer Mositure Titrator

Introduction GDD-1A Automatic Volumetric Karl Fischer Mositure Titrator adopts the newest mechanical-electronic technology with humanistic interface. It is reliable with wide measuring range(0.003%100%), high precision and affordable for users. It can determine crystal water, ...

重庆格纳迪机电设备有限公司

DSHD-2122 Karl Fischer Titrator
DSHD-2122 Karl Fischer Titrator

A:Brief description: DSHD-2122 Karl Fischer Titrator is designed according the National Standard of People's Republic of China GB/T 11133 Liquid petroleum products-Determination of water-Karl Fischer reagent method and the Enterprise Standard of Shanghai City Q/YXYY 14. ...

Zhuhai Dshing Import&Export Co.,ltd

DSHD-2122B Automatic Karl Fischer Titrator
DSHD-2122B Automatic Karl Fischer Titrator

A:Brief description: DSHD-2122B Automatic Karl Fischer Titrator is designed according the National Standard of People's Republic of China GB7600 Test Method for Water Content of Transformer Oil in Service (Coulometric Method), and the Industry Standard of People's Republic of ...

Zhuhai Dshing Import&Export Co.,ltd

DSHD-2122 Karl Fischer Titrator
DSHD-2122 Karl Fischer Titrator

DSHD-2122 Karl Fischer Titrator is designed according the National Standard of People's Republic of China GB/T 11133 Liquid petroleum products-Determination of water-Karl Fischer reagent method and the Enterprise Standard of Shanghai City Q/YXYY 14. DSHD-2122 Karl Fischer ...

1. DSHD-2122B Automatic Karl Fischer Titrator
1. DSHD-2122B Automatic Karl Fischer Titrator

DSHD-2122B Automatic Karl Fischer Titrator is designed according the National Standard of People's Republic of China GB7600 Test Method for Water Content of Transformer Oil in Service (Coulometric Method), and the Industry Standard of People's Republic of China SH/T0246 Test ...

DSHD-2122C Coulometric Karl Fischer Titrator
DSHD-2122C Coulometric Karl Fischer Titrator

The instrument is designed and made as per national standard of China GB/T 7600 Standard Test Method for Water Content of Transformer Oil in Service (Coulometric Method), industrial standard of China SH/T0246 Standard Test Method for Water Content of Light Oils (Coulometry). ...