40G QSFP 1310nm 10km MPO is a parallel 40Gb/s Quad Small Form-factor Pluggable (QSFP+) optical module. It provides increased port density and total system cost savings. The QSFP+ full-duplex
optical module offers 4 independent transmit and receive channels, each capable of 10Gb/s operation for an aggregate data rate of 40Gb/s on 10km of single mode fiber.
An optical QSFP fiber cable with an MTP/MPO connector can be plugged into the QSFP+ module receptacle. Proper alignment is ensured by the guide pins inside the receptacle. The cable usually cannot
be twisted for proper channel to channel alignment. Electrical connection is achieved through a z-pluggable 38-pin connector per MSA requirement.
The module operates with single +3.3V power supply. LVCMOS/LVTTL global control signals, such as Module Present, Reset, Interrupt and Low Power Mode, are available with the modules. A 2-wire serial
interface is available to send and receive more complex control signals, and to receive digital diagnostic information. Individual channels can be addressed and unused channels can be shut down for
maximum design flexibility.
The product is designed with form factor, optical/electrical connection and digital diagnostic interface according to the QSFP+ Multi-Source Agreement (MSA). It has been designed to meet the
harshest external operating conditions including temperature, humidity and EMI interference. The transceiver module can be managed through the I2C two-wire serial interface.
Compatibility of QSFP Transceiver
QSFPP-40GBASE-LR4 40GBASE-LR4 QSFP+ 1310nm 10km
SRX-QSFP-40G-LR4 40GBASE-LR4 QSFP+ 1310nm 10km
JNP-QSFP-40G-LR4 40GBASE-LR4 QSFP+ 1310nm 10km
Technical Specification Of QSFP 40G 1310nm 10km MPO Transceiver
Absolute Maximum Ratings
It has to be noted that the operation in excess of any absolute maximum ratings might cause permanent damage to this module.
Parameter Symbol Min Max Units Notes
Storage Temperature TS -40 85 degC
Operating Case Temperature TOP 0 70 degC
Power Supply Voltage VCC -0.5 3.6 V
Relative Humidity (non-condensation) RH 0 85 %
Damage Threshold, each Lane THd 3.3 dBm
Recommended Operating Conditions and Power Supply Requirements
Parameter Symbol Min Typical Max Units
Operating Case Temperature TOP 0 70 degC
Power Supply Voltage VCC 3.135 3.3 3.465 V
Data Rate, each Lane 10.3125 11.2 Gb/s
Control Input Voltage High 2 Vcc V
Control Input Voltage Low 0 0.8 V
Link Distance with G.652 D 0.002 10 km